2 Parameters
2.2 List of parameters
p9321[0...7]
SI Motion gearbox encoder (motor)/load denom (Motor Module) /
SI Mtn gearDenomMM
VECTOR_G
Can be changed: C2(95)
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
1
Description:
Sets the denominator for the gearbox between the encoder (or motor in the case of encoderless monitoring
functions) and the load.
The active gearbox stage can be switched over via PROFIsafe.
Index:
[0] = Gearbox 1
[1] = Gearbox 2
[2] = Gearbox 3
[3] = Gearbox 4
[4] = Gearbox 5
[5] = Gearbox 6
[6] = Gearbox 7
[7] = Gearbox 8
Dependency:
Refer to: p9322
p9322[0...7]
SI Motion gearbox encoder (motor)/load numerator (Motor Module) /
SI Mtn gear num MM
VECTOR_G
Can be changed: C2(95)
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
1
Description:
Sets the numerator for the gearbox between the encoder (or motor in the case of encoderless monitoring functions)
and the load.
The active gearbox stage can be switched over via PROFIsafe.
Index:
[0] = Gearbox 1
[1] = Gearbox 2
[2] = Gearbox 3
[3] = Gearbox 4
[4] = Gearbox 5
[5] = Gearbox 6
[6] = Gearbox 7
[7] = Gearbox 8
Dependency:
Refer to: p9321
Note:
In the case of encoderless monitoring functions, the pole pair number must be multiplied by the numerator of the
gearbox ratio.
Example:
Gearbox ratio 1:4, pole pair number (r0313) = 2
--> p9321 = 1, p9322 = 8 (4 x 2)
900
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2147000000
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2147000000
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents