2.2 List of parameters
Dependency:
Only valid when p4705 = 4.
p4720[0...1]
Trace recording cycle / Trace record_cyc
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0.000 [ms]
Description:
Sets the recording cycle for the trace.
Index:
[0] = Trace 0
[1] = Trace 1
p4721[0...1]
Trace recording time / Trace record_time
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0.000 [ms]
Description:
Sets the recording time for the trace.
Index:
[0] = Trace 0
[1] = Trace 1
p4722[0...1]
Trace trigger delay / Trace trig_delay
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
-340.28235E36 [ms]
Description:
Sets the trigger delay for the trace.
Trigger delay < 0:
Pretrigger: Tracing (recording) starts the selected time before the trigger event actually occurs.
Trigger delay > 0:
Post trigger: Tracing does not start until the set time after the trigger event.
Index:
[0] = Trace 0
[1] = Trace 1
p4723[0...1]
Trace time slice cycle / Trace cycle
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0.03125 [ms]
Description:
Sets the time slice cycle in which the trace is called.
Index:
[0] = Trace 0
[1] = Trace 1
706
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
60000.000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
340.28235E36 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
340.28235E36 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4.00000 [ms]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
1.000 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
1000.000 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0.000 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0.12500 [ms]