2 Parameters
2.2 List of parameters
p9558
SI Motion acceptance test mode time limit (Control Unit) / SI Mtn acc t CU
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
5000.00 [ms]
Description:
Sets the maximum time for the acceptance test mode.
If the acceptance test mode takes longer than the selected time limit, then the mode is automatically terminated.
Dependency:
Refer to: C01799
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
p9559
SI Motion forced checking procedure timer (Control Unit) / SI Mtn dyn timer
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [h]
Description:
Sets the time interval for carrying out the forced checking procedure and testing the safety motion monitoring
functions integrated in the drives.
Within the parameterized time, the safety functions must have been tested at least once (including de-selection of the
"STO" function).
This monitoring time is reset each time the test is carried out.
The signal source to initiate the forced checking procedure is set in p9705.
Dependency:
Refer to: p9705
Refer to: A01697, C01798
Note:
STO: Safe Torque Off
p9560
SI Motion STO shutdown velocity (Control Unit) / SI Mtn IL v_shutCU
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [mm/min]
Description:
Sets the shutdown velocity for activating STO.
Below this velocity "standstill" is assumed and for STOP B / SS1, STO is selected.
In the case of encoderless motion monitoring functions, the parameter must be > 0 (recommended value: 10).
Dependency:
Refer to: p9556
Note:
The shutdown velocity has no effect for a value = 0.
SS1: Safe Stop 1
p9560
SI Motion pulse suppression shutdown speed (Control Unit) / SI Mtn IL n_shutCU
VECTOR_G (Safety
Can be changed: C2(95)
rot)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the shutdown speed for the pulse suppression.
Below this speed "standstill" is assumed and for STOP B / SS1, the pulses are suppressed (by changing to STOP A).
954
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
100000.00 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
9000.00 [h]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
6000.00 [mm/min]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
6000.00 [rpm]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
40000.00 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
8.00 [h]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [mm/min]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [rpm]
SINAMICS G130/G150