p1270[0...n]
Flying restart configuration / Fly restart config
VECTOR_G
Can be changed: U, T
Data type: Unsigned16
P-Group: Closed-loop control
Not for motor type: PMSM, SESM, REL,
RESM
Min
-
Description:
Sets the configuration for the "flying restart function" function.
Bit field:
Bit
00
01
12
13
14
15
Note:
ASM: Induction motor
PMSM: permanent-magnet synchronous motor
For bit 00:
This bit is equivalent to p1780 bit 1.
For bit 01:
This bit should only be set when required for large drives.
p1271[0...n]
Flying restart maximum frequency for the inhibited direction / FlyRes f_max dir
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [Hz]
Description:
Sets the maximum search frequency for a flying restart in an inhibited setpoint direction (p1110, p1111).
Note:
The parameter has no effect for an operating mode, which only searches in the setpoint direction (p1200 > 3).
p1272
Simulation mode / Simulation mode
VECTOR_G
Can be changed: T
Data type: Integer16
P-Group: Functions
Not for motor type: -
Min
0
Description:
In the simulation mode, the closed-loop control or U/f control can be operated without motor.
The simulation mode is used to test the power unit. Even though the DC link voltage is missing, the pulses are
enabled when switching on. The DC link precharging is bypassed and the undervoltage detection is disabled.
Closed-loop speed control with an encoder is possible if the torque setpoint (r0079) is used in order to operate a
second drive in the closed-loop torque controlled mode.
Value:
0:
1:
Dependency:
The following functions are deactivated in the simulation mode:
- motor data identification routine
- motor data identification routine, rotating without encoder
- pole position identification
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Fast flying restart with voltage model for
induction motor
PLL expansion for fast flying restart w/
voltage model for ASM
Siemens internal
Siemens internal
Siemens internal
Siemens internal
OFF
ON
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
1
1
1
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
650 [Hz]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
0 signal
No
No
No
0
0
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0 [Hz]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
FP
-
-
-
-
-
-
363