[19] = Drive object number object 19
[20] = Drive object number object 20
[21] = Drive object number object 21
[22] = Drive object number object 22
[23] = Drive object number object 23
Notice:
This parameter may only be used by qualified service personnel.
Note:
If the same drive object numbers are used and if the existing drive object numbers in the system are entered
incompletely, the content of this parameter is ignored entirely. The behavior as with factory setting will then become
effective.
r7901[0...81]
Sampling times / t_sample
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
- [µs]
Description:
Displays the sampling times currently present on the drive unit.
r7901[0...63]: sampling times of hardware time slices.
r7901[64...82]: sampling times of software time slices.
r7901[x] = 0, means the following:
No methods have been registered in the time slice involved.
Note:
The basis for the software time slices is T_NRK = p7901[15].
r7903
Hardware sampling times still assignable / HW t_samp free
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the number of hardware sampling times that can still be assigned.
These free sampling times can be used by technology functions such as TEC, DCC or FBLOCKS.
Note:
DCC: Drive Control Chart
FBLOCKS: free blocks
TEC: Technology Extension
p8500[0...7]
BI: Input signal bit-serially 0 / Input_sig bit 0
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32 / Binary
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
-
Description:
Sets the signal source for bit-serial input signals.
These signals are available in binector output r8510.0 ... 7 for further interconnection.
Index:
[0] = To BO: r8510.0
[1] = To BO: r8510.1
[2] = To BO: r8510.2
[3] = To BO: r8510.3
[4] = To BO: r8510.4
[5] = To BO: r8510.5
[6] = To BO: r8510.6
[7] = To BO: r8510.7
Dependency:
Refer to: r8510
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [µs]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [µs]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 2195
Unit selection: -
Expert list: 1
Factory setting
0
799