2 Parameters
2.2 List of parameters
p1051[0...n]
CI: Speed limit RFG positive direction of rotation / n_limit RFG pos
VECTOR_G
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed limit of the positive direction on the ramp-function generator input.
Note:
The OFF3 ramp-down time (p1135) is effective when the limit is reduced.
p1052[0...n]
CI: Speed limit RFG negative direction of rotation / n_limit RFG neg
VECTOR_G
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed limit of the negative direction on the ramp-function generator input.
Note:
The OFF3 ramp-down time (p1135) is effective when the limit is reduced.
p1055[0...n]
BI: Jog bit 0 / Jog bit 0
VECTOR_G
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for jog 1.
Recommendation:
When the setting for this binector input is changed, the motor can only be switched on by means of an appropriate
signal change of the source.
Dependency:
Refer to: p0840, p1058
Notice:
The drive is enabled for jogging using BI: p1055 or BI: p1056.
The command "ON/OFF1" can be issued using BI: p0840 or using BI: p1055/p1056.
Only the signal source that was used to switch on can also be used to switch off again.
p1056[0...n]
BI: Jog bit 1 / Jog bit 1
VECTOR_G
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for jog 2.
Recommendation:
When the setting for this binector input is changed, the motor can only be switched on by means of an appropriate
signal change of the source.
Dependency:
Refer to: p0840, p1059
Notice:
The drive is enabled for jogging using BI: p1055 or BI: p1056.
The command "ON/OFF1" can be issued using BI: p0840 or using BI: p1055/p1056.
Only the signal source that was used to switch on can also be used to switch off again.
316
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: p2000
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: p2000
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 3050
Unit selection: -
Expert list: 1
Factory setting
1083[0]
Access level: 3
Func. diagram: 3050
Unit selection: -
Expert list: 1
Factory setting
1086[0]
Access level: 3
Func. diagram: 2501, 3030
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2501, 3030
Unit selection: -
Expert list: 1
Factory setting
0