2 Parameters
2.2 List of parameters
Dependency:
Refer to: p3829, p3845
p3860
Number of Braking Modules connected in parallel / BM qty par_cct
B_INF (Brk Mod ext)
Can be changed: C2(2)
Data type: Unsigned8
P-Group: Converter
Not for motor type: -
Min
1
Description:
Sets the number of Braking Modules connected in parallel in a DC link.
Note:
The parameter can only be written to if the infeed is in the commissioning mode (p0010 = 2).
r3861.0...7
BO: Braking Module inhibit/acknowledgment / BM inhib/ackn
B_INF (Brk Mod ext)
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Signal to energize terminal X21.1 "inhibit/acknowledgment" on the Braking Module.
This binector output is used as signal source to interconnect to a digital output.
For "booksize" formats the digital output must be connected to terminal X21.1 and for "chassis" formats the digital
output must be connected to terminal X21.3 of the particular Braking Module.
Bit field:
Bit
00
01
02
03
04
05
06
07
Warning:
Check that binector outputs BO: r3861.n are connected correctly and that the appropriate digital outputs are wired
correctly.
If the interconnection/wiring is incorrect, the software could execute a different (incorrect) function via binector
outputs BO: r3861.n if the Braking Module develops a fault.
p3862
Braking Module DC link fast discharge delay time / BM DC-dischg t_del
B_INF (Brk Mod ext)
Can be changed: C1(3), T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
500 [ms]
Description:
Sets the delay time for switching in the DC link fast discharge.
Dependency:
Refer to: p3863, r3864
Note:
The DC link fast discharge is only possible for "booksize" formats. This function is not supported for "chassis"
formats.
628
Signal name
Inhibit/acknowledge Braking Module 1
Inhibit/acknowledge Braking Module 2
Inhibit/acknowledge Braking Module 3
Inhibit/acknowledge Braking Module 4
Inhibit/acknowledge Braking Module 5
Inhibit/acknowledge Braking Module 6
Inhibit/acknowledge Braking Module 7
Inhibit/acknowledge Braking Module 8
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
8
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
High
High
High
High
High
High
High
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4294967295 [ms]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 9951
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 9951
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Low
Low
Low
Access level: 3
Func. diagram: 9951
Unit selection: -
Expert list: 1
Factory setting
1000 [ms]