r0687[0...7]
CO: Central measuring probe measuring time falling edge / CenMeas t_meas 1/0
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: Displays, signals
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the measuring time for a falling edge at the digital input for the "central measuring probe evaluation"
function.
The measuring time is specified as 16-bit value with a resolution of 0.25 µs.
r0687[0]: Measuring time, falling edge measuring probe 1
r0687[1]: Measuring time, falling edge measuring probe 2
r0687[2]: Measuring time, falling edge measuring probe 3
r0687[3]: Measuring time, falling edge measuring probe 4
r0687[4]: Measuring time, falling edge measuring probe 5
r0687[5]: Measuring time, falling edge measuring probe 6
r0687[6]: Measuring time, falling edge measuring probe 7
r0687[7]: Measuring time, falling edge measuring probe 8
Note:
The parameter is only active for the evaluation procedure p0684 = 0, 1.
For p0684 = 16, r0687[0...7] = 0 is displayed.
r0688
CO: Central measuring probe status word display / Cen meas ZSW disp
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: Displays, signals
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the status word for the function "central measuring probe evaluation".
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Digital input measuring probe 1
Digital input measuring probe 2
Digital input measuring probe 3
Digital input measuring probe 4
Digital input measuring probe 5
Digital input measuring probe 6
Digital input measuring probe 7
Digital input measuring probe 8
Sub-sampling measuring probe 1
Sub-sampling measuring probe 2
Sub-sampling measuring probe 3
Sub-sampling measuring probe 4
Sub-sampling measuring probe 5
Sub-sampling measuring probe 6
Sub-sampling measuring probe 7
Sub-sampling measuring probe 8
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
251