2 Parameters
2.2 List of parameters
Note:
For distance-coded zero marks this parameter signifies the basic distance.
p0426[0...n]
Encoder zero mark differential distance / Enc ZM Dif_dist
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
1
Description:
Sets the differential distance with distance-coded zero marks [signal periods].
The value corresponds to jump displacement of "zero mark with interference".
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
p0427[0...n]
Encoder SSI baud rate / Enc SSI baud rate
VECTOR_G, ENC
Can be changed: C2(4)
Data type: FloatingPoint32
P-Group: Encoder
Not for motor type: -
Min
0 [kHz]
Description:
Sets the baud rate for an SSI encoder.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
SSI: Synchronous Serial Interface
p0428[0...n]
Encoder SSI monoflop time / Enc SSI t_monoflop
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
0 [µs]
Description:
Sets the minimum delay time between two data transfers of the absolute value for an SSI encoder.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
p0429[0...n]
Encoder SSI configuration / Enc SSI config
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Sets the configuration for an SSI encoder.
Bit field:
Bit
00
02
06
172
Signal name
Transfer code
Transfer absolute value twice
Data line during the monoflop time
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
65535 [kHz]
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
65535 [µs]
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
-
1 signal
Binary code
Yes
High level
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100 [kHz]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
30 [µs]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 bin
0 signal
Gray code
No
Low level
SINAMICS G130/G150
FP
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150