Siemens G130 List Manual page 791

Hide thumbs Also See for G130:
Table of Contents

Advertisement

Index:
[0] = Sum of the following indices
[1] = Object number in p0101[0]
[2] = Object number in p0101[1]
[3] = Object number in p0101[2]
[4] = Object number in p0101[3]
[5] = Object number in p0101[4]
[6] = Object number in p0101[5]
[7] = Object number in p0101[6]
[8] = Object number in p0101[7]
[9] = Object number in p0101[8]
[10] = Object number in p0101[9]
[11] = Object number in p0101[10]
[12] = Object number in p0101[11]
[13] = Object number in p0101[12]
[14] = Object number in p0101[13]
[15] = Object number in p0101[14]
[16] = Object number in p0101[15]
[17] = Object number in p0101[16]
[18] = Object number in p0101[17]
[19] = Object number in p0101[18]
[20] = Object number in p0101[19]
[21] = Object number in p0101[20]
[22] = Object number in p0101[21]
[23] = Object number in p0101[22]
[24] = Object number in p0101[23]
Dependency:
Refer to: p0101, r7867, r7872
r7870[0...7]
Configuration changes global / Config_chng global
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the configuration changes of all of the drive objects in the complete unit.
Index:
[0] = Sum of the following indices
[1] = r7871[0] of a drive object
[2] = p0101 or r0102
[3] = PROFIBUS configuration (p0978)
[4] = DRIVE-CLiQ actual topology (r9900 or r9901)
[5] = DRIVE-CLiQ target topology (r9902 or r9903)
[6] = DRIVE-CLiQ sockets (p0109)
[7] = Technology Extensions
Dependency:
Refer to: r7867, r7871
Note:
For index 0:
When changing one of the following indices, then the value in this index is incremented.
For index 1:
Drive object configuration. When changing r7871[0] on a drive object, the value in this index is incremented.
For index 2:
Drive object, configuration unit. When changing either p0101 or r0102, the value in this index is incremented.
For index 3:
PROFIBUS configuration unit. When changing p0978, the value in this index is incremented.
For index 4:
DRIVE-CLiQ actual topology. When changing either r9900 or r9901, the value in this index is incremented.
For index 5:
DRIVE-CLiQ target topology. When changing either p9902 or p9903, the value in this index is incremented.
For index 6:
DRIVE-CLiQ sockets. When changing p0109, the value in this index is incremented.
For index 7:
Technology Extensions When changing Technology Extensions, the value in this index is incremented.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
791

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents