Siemens G130 List Manual page 839

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p8815[0...1]
IF1/IF2 PZD functionality selection / IF1/IF2 PZD fct
CU_G130_PN,
Can be changed: C1(1)
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: Communications
CU_G150_DP
Not for motor type: -
Min
1
Description:
Selects the PZD interface for the clock cycle synchronization functionality and PROFIsafe.
Value:
1:
2:
Index:
[0] = Isochronous mode
[1] = PROFIsafe
Dependency:
Refer to: p8839
Note:
A change only becomes effective after POWER ON, reset or project download.
Example:
p8815[0] = 1: IF1 supports the isochronous mode.
p8815[1] = 2: IF2 supports PROFIsafe.
p8829
CBE2x remote controller number / CBE2x rem ctrl num
CU_G130_PN (PN
Can be changed: C1(1)
CBE20),
Data type: Integer16
CU_G150_PN (PN
P-Group: Communications
CBE20),
Not for motor type: -
CU_G130_DP (PN
CBE20),
Min
CU_G150_DP (PN
1
CBE20)
Description:
Sets the number of remote controllers expected for PROFINET CBE20/CBE25.
The "Shared Device" functionality is activated with a value = 2.
The drive is being accessed by two PROFINET controllers simultaneously:
- automation controller (SIMOTION or SIMATIC A-CPU).
- safety controller (SIMATIC F-CPU).
Value:
1:
2:
Notice:
The F CPU may only use PROFIsafe telegrams.
The A CPU must be connected to enable the F CPU to gain access.
Set the value = 1 to commission the F CPU individually.
Note:
A change only becomes effective after a POWER ON.
p8835
CBE20 firmware selection / CBE20 FW sel
CU_G130_PN (PN
Can be changed: C1(1)
CBE20),
Data type: Integer16
CU_G150_PN (PN
P-Group: Communications
CBE20),
Not for motor type: -
CU_G130_DP (PN
CBE20),
Min
CU_G150_DP (PN
1
CBE20)
Description:
Selects the firmware version for the CBE20.
Value:
1:
2:
3:
4:
5:
99:
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Interface 1 (IF1)
Interface 2 (IF2)
Automation or Safety
Automation and Safety
PROFINET Device
PROFINET gate
SINAMICS Link
EtherNet/IP
Modbus TCP
Customer-specific from the OEM directory
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
99
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 2197, 2198
Unit selection: -
Expert list: 1
Factory setting
1
839

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents