2 Parameters
2.2 List of parameters
r0980[0...299]
List of existing parameters 1 / List avail par 1
All objects
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the parameters that exist for this drive.
Dependency:
Refer to: r0981, r0989
Note:
Modified parameters are displayed in indices 0 to 298. If an index contains the value 0, then the list ends here. In a
long list, index 299 contains the parameter number at which position the list continues.
This list consists solely of the following parameters:
r0980[0...299], r0981[0...299] ... r0989[0...299]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be
read from a higher-level control system (e.g. PROFIBUS master).
r0981[0...299]
List of existing parameters 2 / List avail par 2
All objects
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the parameters that exist for this drive.
Dependency:
Refer to: r0980, r0989
Note:
Modified parameters are displayed in indices 0 to 298. If an index contains the value 0, then the list ends here. In a
long list, index 299 contains the parameter number at which position the list continues.
This list consists solely of the following parameters:
r0980[0...299], r0981[0...299] ... r0989[0...299]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be
read from a higher-level control system (e.g. PROFIBUS master).
r0989[0...299]
List of existing parameters 10 / List avail par 10
All objects
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the parameters that exist for this drive.
Dependency:
Refer to: r0980, r0981
Note:
Modified parameters are displayed in indices 0 to 298. If an index contains the value 0, then the list ends here.
This list consists solely of the following parameters:
r0980[0...299], r0981[0...299] ... r0989[0...299]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be
read from a higher-level control system (e.g. PROFIBUS master).
304
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH2), 07/2016, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
SINAMICS G130/G150