2 Parameters
2.2 List of parameters
Note:
The reference value for power and speed is the rated power/rated speed.
The energy saved is displayed in r0041.
r3402
Infeed status internal BIC / INF state int
B_INF
Can be changed: -
Data type: Integer16
P-Group: Closed-loop control
Not for motor type: -
Min
0
Description:
Displays the internal status of the infeed module.
Value:
0:
1:
2:
3:
4:
5:
6:
r3405.1...8
CO/BO: Status word DC link control / ZSW Vdc_ctrl
VECTOR_G
Can be changed: -
(Tech_ctrl)
Data type: Unsigned16
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Display and BICO output for the status word of the DC link voltage control.
Bit field:
Bit
01
08
Dependency:
Refer to: A06810
Note:
For bit 01:
DC link voltage control is disabled and enabled with p3513.
For bit 08 = 1:
DC link voltage control is selected using p3513.
r3405.7
CO/BO: Infeed status word / Inf ZSW
B_INF
Can be changed: -
Data type: Unsigned16
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Display and BICO output for the status word of the infeed unit.
Bit field:
Bit
07
Dependency:
Refer to: A06810
Note:
For bit 07:
When the alarm threshold is fallen below, alarm A06810 is output and r3405.7 is set = 1.
The alarm threshold is obtained from the sum of the undervoltage threshold p0296 and offset r0279. As a
consequence, the alarm threshold is only effective for p0279 > 0.
Monitoring only takes place when operational.
The following applies for states r3402 <= 5 and r3402 = 12: r3405.7 = 0.
606
Initialization
Fault
No ON command
Offset measurement running
ON delay active
Precharging running
Operation
Signal name
Vdc-ctrl active
Vdc controller selected
Signal name
DC link undervoltage alarm threshold
undershot
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
6
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: 8932
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
SINAMICS G130/G150
FP
-
-
FP
-