Siemens G130 List Manual page 44

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p0010
TB30 commissioning parameter filter / TB30 comm.par_filt
TB30
Can be changed: C2(1), T
Data type: Integer16
P-Group: All groups
Not for motor type: -
Min
0
Description:
Sets the parameter filter for commissioning a Terminal Board 30 (TB30).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
29:
30:
Dependency:
Refer to: p0970
Note:
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
p0010
TM54F commissioning parameter filter / TM54F com par_filt
TM54F_MA
Can be changed: C2(1), T
Data type: Integer16
P-Group: All groups
Not for motor type: -
Min
0
Description:
Sets the parameter filter for commissioning a Terminal Module 54F (TM54F).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
29:
30:
95:
Dependency:
Refer to: p0970
Note:
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
p0010
Encoder DO commissioning parameter filter / EncDO com par_filt
ENC
Can be changed: C2(1), T
Data type: Integer16
P-Group: All groups
Not for motor type: -
Min
0
Description:
Sets the parameter filter to commission an encoder drive object.
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
4:
5:
29:
30:
Note:
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
44
Ready
Only Siemens int
Parameter reset
Ready
Only Siemens int
Parameter reset
Safety Integrated commissioning
Ready
Encoder commissioning
Technological application/units
Only Siemens int
Parameter reset
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
30
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
95
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
30
List Manual (LH2), 07/2016, A5E03263479A
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 2891
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0