r1508
CO: Torque setpoint before supplementary torque / M_set bef. M_suppl
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Nm]
Description:
Displays the torque setpoint before entering the supplementary torque.
For closed-loop speed control, r1508 corresponds to the speed controller output; for closed-loop torque control,
r1508 corresponds to the torque setpoint of the signal source assigned in p1503.
p1511[0...n]
CI: Supplementary torque 1 / M_suppl 1
VECTOR_G (n/M)
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the signal source for supplementary torque 1.
p1512[0...n]
CI: Supplementary torque 1 scaling / M_suppl 1 scal
VECTOR_G (n/M)
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the signal source for scaling the supplementary torque 1.
p1513[0...n]
CI: Supplementary torque 2 / M_suppl 2
VECTOR_G (n/M)
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the signal source for supplementary torque 2.
p1514[0...n]
Supplementary torque 2 scaling / M_suppl 2 scal
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-2000.0 [%]
Description:
Sets the scaling for supplementary torque 2.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: p2003
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: p2003
Max
-
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
2000.0 [%]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6030, 6060,
6722
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: 6020, 6060
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 5060, 6060
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 6020, 6060
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 6020, 6060
Unit selection: -
Expert list: 1
Factory setting
100.0 [%]