2 Parameters
2.2 List of parameters
p9351
SI Motion SLS(SG) changeover/SOS (SBH) delay time (MM) / SI SLS/SOS t MM
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the delay time for the SLS changeover and for the activation of SOS for the functions "Safely Limited Speed"
(SLS) and "Safe Operating Stop" (SOS).
When transitioning from a higher to a lower safely limited speed level, and when activating safe operating stop
(SOS), within this delay time, the "old" speed level remains active.
This delay is also applicable when activating SLS from the state "SOS and SLS inactive" and activating SOS from the
state "SOS inactive".
Dependency:
Refer to: p9551
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SLS: Safely Limited Speed
SOS: Safe Operating Stop
p9352
SI Motion transition time STOP C to SOS (Motor Module) / SI Mtn t C->SOS MM
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the transition time from STOP C to "Safe Operating Stop" (SOS).
Dependency:
Refer to: p9552
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SOS: Safe Operating Stop
p9353
SI Motion transition time STOP D to SOS (Motor Module) / SI Mtn t D->SOS MM
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the transition time from STOP D to "Safe Operating Stop" (SOS).
Dependency:
Refer to: p9553
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SOS: Safe Operating Stop
910
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
600000000.00 [µs]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
600000000.00 [µs]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
600000000.00 [µs]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 2819, 2820
Unit selection: -
Expert list: 1
Factory setting
100000.00 [µs]
Access level: 3
Func. diagram: 2819
Unit selection: -
Expert list: 1
Factory setting
100000.00 [µs]
Access level: 3
Func. diagram: 2819
Unit selection: -
Expert list: 1
Factory setting
100000.00 [µs]