r1624
Field-generating current setpoint total / Id_setp total
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: REL
Min
- [Arms]
Description:
Displays the limited field-generating current setpoint (Id_set).
This value comprises the steady-state field-generating current setpoint r1623 and a dynamic component that is only
set when changes are made to the flux setpoint.
p1625[0...n]
Excitation current setpoint calibration / I_exc_setp cal
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, REL
Min
10.0 [%]
Description:
Sets the gain factor to weight the excitation current setpoint.
r1626[0...1]
CO: Excitation current setpoint / I_exc_setp
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, REL
Min
- [%]
Description:
Displays the calculated excitation current setpoint.
The following applies for index 0:
For direct excitation, the value is referred to p0390. For brushless excitation, the value is referred to p0690.
The following applies for index 1:
The value is referred to p0390.
Index:
[0] = Excitation current of the excitation equipment
[1] = Excitation current for direct excitation
Dependency:
Refer to: p0390, p0690
r1627
CO: Current model load angle / I_mod load angle
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, REL
Min
- [°]
Description:
Displays the load angle of the current model.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
200.0 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2005
Max
- [°]
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: 6640, 6721,
6723, 6727
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 3
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
100.0 [%]
Access level: 3
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
- [°]
429