2 Parameters
2.2 List of parameters
p0133[0...n]
Motor configuration / Motor config
VECTOR_G
Can be changed: C2(1, 3)
Data type: Unsigned16
P-Group: Motor
Not for motor type: PMSM, SESM, REL
Min
-
Description:
Configuration of the motor when commissioning the motor.
Bit field:
Bit
00
Dependency:
For standard induction motors (p0301 > 10000), bit 0 is automatically pre-assigned the connection type of the
selected data set.
For p0100 > 0 (60 Hz rated motor frequency), it is not possible to select bit 1.
Refer to: p0304, p0305
Note:
For bit 00:
When changing the bits, the rated motor voltage p0304 and the rated motor current p0305 are automatically
converted to the selected connection type (star/delta).
For instance, this can be necessary if an 1LE1 motor is selected using the Article number (MLFB) or code number
(p0300 = 100, p0301 = 1x0xx), and the motor connection type does not correspond to that of the data set.
p0139[0...2]
Copy Motor Data Set MDS / Copy MDS
VECTOR_G
Can be changed: C2(15)
Data type: Unsigned8
P-Group: Data sets
Not for motor type: -
Min
0
Description:
Copying a Motor Data Set (MDS) into another.
Index:
[0] = Source motor data set
[1] = Target motor data set
[2] = Start copying procedure
Note:
Procedure:
1. In Index 0, enter which motor data set should be copied.
2. In Index 1, enter the motor data set data that is to be copied into.
3. Start copying: set index 2 from 0 to 1.
p0139[2] is automatically set to 0 when copying is completed.
When copying, p0131 is not taken into account.
p0140
Number of Encoder Data Sets (EDS) / EDS count
VECTOR_G
Can be changed: C1(3)
Data type: Unsigned8
P-Group: Data sets
Not for motor type: -
Min
1
Description:
Sets the number of Encoder Data Sets (EDS).
Note:
When parameterizing the drive with "no encoder" there must be at least one encoder data set (p0140 >= 1).
94
Signal name
Motor connection type
Calculated: -
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
-
1 signal
Delta
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
31
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
16
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
Star
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 8570
Unit selection: -
Expert list: 1
Factory setting
1