Siemens G130 List Manual page 428

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p1619[0...n]
Setpoint/actual value tracking threshold / SetAct track thrsh
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, REL
Min
0.00 [Arms]
Description:
Threshold for setpoint/actual value tracking of the stator current in the q axis of the current model.
p1620[0...n]
Stator current minimum / I_stator min
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, REL
Min
-10000.00 [Arms]
Description:
Sets the minimum stator current for separately excited synchronous motors (SESM).
A negative value means that the field-generating stator current (d-axis) has a negative sign. The valid value is
internally limited to 50% of the rated motor current (p0305).
p1621[0...n]
Changeover speed inner cos phi = 1 / n_chngov cos phi=1
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, REL
Min
0.00 [rpm]
Description:
Sets the speed where a change is made from the inner to the outer cos phi = 1.
If the value that is entered exceeds the rated speed, then a change is made to the inner cos phi = 1 over the complete
speed range.
p1622[0...n]
Field-generating current setpoint smoothing time constant / Id_setp T_smth
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, REL
Min
0.1 [ms]
Description:
Sets the smoothing time constant for the setpoint of the field-generating current components.
The current filtered in this way is included in the calculation of the cos phi.
r1623[0...1]
Field-generating current setpoint (steady-state) / Id_set stationary
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: PMSM, REL
Min
- [Arms]
Description:
Displays the steady-state field generating current setpoint (Id_set).
428
Calculated: CALC_MOD_ALL
Dyn. index: DDS, p0180
Unit group: 6_2
Scaling: p2002
Max
10000.00 [Arms]
Calculated: CALC_MOD_ALL
Dyn. index: DDS, p0180
Unit group: 6_2
Scaling: -
Max
10000.00 [Arms]
Calculated: CALC_MOD_ALL
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
200.0 [ms]
Calculated: -
Dyn. index: -
Unit group: 6_2
Scaling: p2002
Max
- [Arms]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 6727
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [Arms]
Access level: 3
Func. diagram: 6727
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [Arms]
Access level: 3
Func. diagram: 6727
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [rpm]
Access level: 3
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
20.0 [ms]
Access level: 4
Func. diagram: 6723, 6726,
6727
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents