r8515
CO: Output signal wordwise 3 / Outp_sig word 3
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: FloatingPoint32
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the signal interconnected via connector input p8505.
Dependency:
Refer to: p8505
p8550
AOP LOCAL/REMOTE / AOP LOCAL/REMOTE
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
-
Description:
Setting for saving the actual configuration of the Advanced Operator Panel (AOP).
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
14
15
p8552
IOP speed unit / IOP speed unit
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
1
Description:
Sets the unit for displaying and entering speeds.
Value:
1:
2:
r8570[0...39]
Macro drive object / Macro DO
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: -
CU_G150_DP,
Not for motor type: -
VECTOR_G, B_INF,
TM31, TM120, TM150
Min
-
Description:
Displays the macro file saved in the appropriate directory on the memory card/device memory.
Dependency:
Refer to: p0015
Note:
For a value = 9999999, the following applies: The read operation is still running.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
LOCAL save
Start in LOCAL
Change in oper
OFF acts like OFF1
OFF acts like OFF2
OFF acts like OFF3
Reserved
CW/CCW active
Jog active
Save speed setpoint
Inhibit operation
Inhibit parameterization
Hz
rpm
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 2195
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 1001 bin
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
FP
-
-
-
-
-
-
-
-
-
-
-
-