2 Parameters
2.2 List of parameters
p1008[0...n]
CO: Fixed speed setpoint 8 / n_set_fixed 8
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 8.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1009[0...n]
CO: Fixed speed setpoint 9 / n_set_fixed 9
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 9.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1010[0...n]
CO: Fixed speed setpoint 10 / n_set_fixed 10
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 10.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1011[0...n]
CO: Fixed speed setpoint 11 / n_set_fixed 11
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-210000.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 11.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
308
Calculated: -
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: p2000
Max
210000.000 [rpm]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]