Siemens G130 List Manual page 941

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p9535[0...1]
SI Motion SLP (SE) lower limit values (Control Unit) / SI Mtn SLP low lim
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
-2147000.000 [mm]
Description:
Sets the lower limit for the function "Safely Limited Position" (SLP).
Index:
[0] = Limit value SLP1 (SE1)
[1] = Limit value SLP2 (SE2)
Dependency:
Refer to: p9501, p9534, p9562
Refer to: C01715
Note:
The following applies to the setting of these limits:
- p9534[x] > p9535[x]
- p9535[x] must lie in the valid traversing range (-737280 ... 737280).
SLP: Safely Limited Position / SE: Safe software limit switches
p9535[0...1]
SI Motion SLP (SE) lower limit values (Control Unit) / SI Mtn SLP low lim
VECTOR_G (Safety
Can be changed: C2(95)
rot)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
-2147000.000 [°]
Description:
Sets the lower limit for the function "Safely Limited Position" (SLP).
Index:
[0] = Limit value SLP1 (SE1)
[1] = Limit value SLP2 (SE2)
Dependency:
Refer to: p9501, p9534, p9562
Refer to: C01715
Note:
The following applies to the setting of these limits:
- p9534[x] > p9535[x]
- p9535[x] must lie in the valid traversing range (-737280 ... 737280).
SLP: Safely Limited Position / SE: Safe software limit switches
p9536[0...29]
SI Motion SCA (SN) plus cam position (Control Unit) / SI Mtn SCA+
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
-2147000.000 [mm]
Description:
Sets the plus cam position for the function "Safe Cam" (SCA).
Index:
[0] = Cam position SCA1 (SN1)
[1] = Cam position SCA2 (SN2)
[2] = Cam position SCA3 (SN3)
[3] = Cam position SCA4 (SN4)
[4] = Cam position SCA5 (SN5)
[5] = Cam position SCA6 (SN6)
[6] = Cam position SCA7 (SN7)
[7] = Cam position SCA8 (SN8)
[8] = Cam position SCA9 (SN9)
[9] = Cam position SCA10 (SN10)
[10] = Cam position SCA11 (SN11)
[11] = Cam position SCA12 (SN12)
[12] = Cam position SCA13 (SN13)
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2147000.000 [mm]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2147000.000 [°]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2147000.000 [mm]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2822
Unit selection: -
Expert list: 1
Factory setting
-100000.000 [mm]
Access level: 3
Func. diagram: 2822
Unit selection: -
Expert list: 1
Factory setting
-100000.000 [°]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
10.000 [mm]
941

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents