p4073[0...1]
TB30 analog outputs smoothing time constant / TB30 AO T_smooth
TB30
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
0.0 [ms]
Description:
Sets the smoothing time constant of the 1st order lowpass filter for the analog outputs of the Terminal Board 30
(TB30).
Index:
[0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
r4074[0...1]
TM31 analog outputs current output voltage/current / TM31 AO U/I_outp
TM31
Can be changed: -
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
-
Description:
Displays the actual output voltage in V when set as voltage output.
Displays the actual output voltage in mA when set as current output.
Index:
[0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Dependency:
The type of the analog output AO x (voltage or current output) is set using p4076.
Refer to: r4076, p4076
Note:
AO: Analog Output
r4074[0...1]
TB30 analog outputs actual output voltage / TB30 AO U_outp
TB30
Can be changed: -
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
- [V]
Description:
Displays the actual output voltage at the analog outputs of the Terminal Board 30 (TB30).
Index:
[0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
p4075[0...1]
TM31 analog outputs activate absolute value generation / TM31 AO absVal act
TM31
Can be changed: T
Data type: Integer16
P-Group: Terminals
Not for motor type: -
Min
0
Description:
Activates the absolute value generation for the analog outputs of Terminal Module 31 (TM31).
Value:
0:
1:
Index:
[0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
No absolute value generation
Absolute value generation switched in
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1000.0 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2001
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [V]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: 9106
Unit selection: -
Expert list: 1
Factory setting
0.0 [ms]
Access level: 1
Func. diagram: 9572
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: 9106
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 3
Func. diagram: 9572
Unit selection: -
Expert list: 1
Factory setting
0
657

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents