Siemens G130 List Manual page 190

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
25
26
27
28
29
30
31
Dependency:
Refer to: p0437, p0600, p0601
Note:
A value of zero is displayed if an encoder is not present.
For bit 11:
When the property is set, the following parameters can be changed without the actual value in the encoder interface
becoming invalid (state r0481.14 = 1 "parking encoder active"):
p0314, p0315, p0430, p0431, p0441, p0442, p0443, p0444, p0445
For bit 12:
The extended functions can be configured using p0437.
For bit 13:
Encoder faults can be acknowledged via Gn_STW.15.
For bit 14:
Only for internal Siemens use.
For bit 23:
When the property is set, commutation with zero mark can be de-selected using p0430.23.
For bit 24:
If the property is set, commutation to the selected zero mark can be carried out.
r0459[0...2]
Sensor Module properties extended / SM prop ext
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the extended properties supported by the Sensor Module.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Bit field:
Bit
00
01
02
04
05
06
07
09
10
11
12
13
14
15
16
17
18
23
24
190
Disconnection of encoder power supply on
parking supported
Parking with temperature evaluation
SSI position value extrapolation
Cubic correction
Phase correction
Amplitude correction
Offset correction
Signal name
Data logger
Zero mark edge detection
Correction position actual value XIST1
Edge evaluation bit 0
Edge evaluation bit 1
Freeze the speed actual value for dn/dt
errors
Accumulate uncorrected encoder pulses
Function p0426, p0439 supported
Pulse/direction interface
Fault handling after PROFIdrive
Activate additional messages
Absolute position for incremental encoder
supported
Spindle functionality
Additional temperature sensor available
Internal encoder temperature available
Extended multiturn resolution
PT1000 temperature sensor evaluation
Commutation with 180°
Multiturn via battery
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
List Manual (LH2), 07/2016, A5E03263479A
No
No
No
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
SINAMICS G130/G150
-
-
-
-
-
-
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents