Siemens G130 List Manual page 620

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Note:
Synchronism is reached (r3819.2 = 1), if the AND logic operation of the results from the phase measurement (p3813)
and voltage measurement (p3815) is fulfilled.
For voltage manipulated quantity margin (reserve) of the drive converter, the amplitude difference (r3814) between
the setpoint and actual value is controlled (corrected) to zero.
r3819.0...7
CO/BO: Sync-line-drive status word / Sync ZSW
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Functions
Not for motor type: -
Min
-
Description:
Displays the status word for the line-drive synchronization.
Bit field:
Bit
00
02
03
05
06
07
p3820[0...n]
Friction characteristic value n0 / Friction n0
VECTOR_G (n/M)
Can be changed: T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: REL
Min
0.00 [rpm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 1st value pair of the friction characteristic.
Dependency:
Refer to: p3830, p3845
p3821[0...n]
Friction characteristic value n1 / Friction n1
VECTOR_G (n/M)
Can be changed: T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: REL
Min
0.00 [rpm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 2nd value pair of the friction characteristic.
Dependency:
Refer to: p3831, p3845
620
Signal name
Sync-line-drive enabled
Sync-line-drive synchronism reached
Sync-line-drive synchronizing error
Sync-line-drive frequency measurement
active
Sync-line-drive phase control active
Sync-line-drive without drive
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: -
Max
210000.00 [rpm]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: 7020
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
15.00 [rpm]
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
30.00 [rpm]
SINAMICS G130/G150
FP
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents