Siemens G130 List Manual page 719

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p4785[0...1]
Trace physical address signal 5 / Trace PhyAddr Sig5
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0000 bin
Description:
Sets the physical address for the sixth signal to be traced.
The data type is defined using p4735.
Index:
[0] = Trace 0
[1] = Trace 1
p4786[0...1]
Trace physical address signal 6 / Trace PhyAddr Sig6
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0000 bin
Description:
Sets the physical address for the seventh signal to be traced.
The data type is defined using p4736.
Index:
[0] = Trace 0
[1] = Trace 1
p4787[0...1]
Trace physical address signal 7 / Trace PhyAddr Sig7
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0000 bin
Description:
Sets the physical address for the eighth signal to be traced.
The data type is defined using p4737.
Index:
[0] = Trace 0
[1] = Trace 1
p4789[0...1]
Trace physical address trigger signal / Trace PhyAddr Trig
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0000 hex
Description:
Sets the physical address for the trigger signal.
The data type is defined by making the appropriate selection in p4711.
Index:
[0] = Trace 0
[1] = Trace 1
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1111 1111 1111 1111 1111 1111
1111 1111 bin
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1111 1111 1111 1111 1111 1111
1111 1111 bin
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1111 1111 1111 1111 1111 1111
1111 1111 bin
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
FFFF FFFF hex
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 bin
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 bin
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 bin
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 hex
719

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: