Siemens G130 List Manual page 742

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Dependency:
Refer to: r0034
Note:
Users cannot see and change parameter p0613 (only Siemens internal).
r5398[0...n]
Mot_temp_mod 3 alarm threshold image p5390 / A thr image p5390
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: ASM, SESM, REL
Min
- [°C]
Description:
Displays the alarm threshold for monitoring the motor temperature for motor temperature model 3.
This value is used to calculate the utilization display (p0034).
The parameter value is an image of p5390.
Dependency:
Refer to: p5390
Refer to: F07011, A07012, A07014
Note:
Users cannot see and change parameter p5390 (only Siemens internal).
r5399[0...n]
Mot_temp_mod 3 fault threshold image p5391 / F thr image p5391
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: ASM, SESM, REL
Min
- [°C]
Description:
Sets the fault threshold for monitoring the motor temperature for motor temperature model 3.
Fault F07011 is output after the fault threshold is exceeded.
The parameter value is an image of p5391.
Dependency:
Refer to: p5391
Refer to: F07011, A07012, A07014
Note:
Users cannot see and change parameter p5391 (only Siemens internal).
r5600
Pe energy-saving mode ID / Pe mode ID
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: Communications
CU_G150_DP
Not for motor type: -
Min
0
Description:
Displays the PROFIenergy mode ID of the effective energy-saving mode.
Value:
0:
2:
240:
255:
Note:
Pe: PROFIenergy profiles
742
POWER OFF
Energy-saving mode 2
Operation
Ready
Calculated: -
Dyn. index: MDS, p0130
Unit group: 21_1
Scaling: -
Max
- [°C]
Calculated: -
Dyn. index: MDS, p0130
Unit group: 21_1
Scaling: -
Max
- [°C]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: 8019
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]
Access level: 2
Func. diagram: 8019
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]
Access level: 3
Func. diagram: 2381, 2382
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents