Siemens G130 List Manual page 729

Hide thumbs Also See for G130:
Table of Contents

Advertisement

Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: r4841, p4844
Refer to: A02097, A02098
Notice:
A multiple trace can have a negative impact on the total system performance.
From their inherent principle of operation, flash memory cards are subject to wear as a result of write operations. As
a consequence, the lifetime of flash memory cards is reduced when using the multiple trace functionality.
r4841[0...1]
MTrace cycle actual display / Cycle act display
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the currently running cycle (including deadtime) of the multiple trace.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: p4840, p4844
p4844[0...1]
MTrace ring buffer files number / Ring buff file qty
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
10
Description:
Sets the number of ring buffer files for the measurement results of the multiple trace.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: p4840, r4841
r4950
TEC DO-specific number / TEC DO qty
All objects
Can be changed: -
Data type: Unsigned16
P-Group: OEM range
Not for motor type: -
Min
0
Description:
Number of Technology Extensions installed on this drive object.
Dependency:
Refer to: r4951, r4952, r4955, p4956, r4957, r4958, r4959, r4960
Note:
DO: Drive Object
TEC: Technology Extension
r4951
TEC DO-specific identifier total length / TEC DO ident tot_l
All objects
Can be changed: -
Data type: Unsigned16
P-Group: OEM range
Not for motor type: -
Min
0
Description:
Displays the total length of the identifiers of the Technology Extensions installed on this drive object.
Dependency:
Refer to: r4950, r4952, r4955, p4956, r4957, r4958, r4959, r4960
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
16
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
144
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
10
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
729

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents