2 Parameters
2.2 List of parameters
p9546
SI Motion SSM (SGA n < nx) velocity limit (CU) / SI Mtn SSM v_limCU
VECTOR_G (Safety
Can be changed: C2(95)
rot)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the velocity limit for the SSM feedback signal to detect standstill (n < nx).
When this limit value is undershot, the signal "SSM feedback signal active" (SGA n < n_x) is set.
For p9568 = 0, the value in p9546 is also applicable for SAM/SBR.
Caution:
The following applies for p9506 = 3:
The "SAM/SBR" function is deactivated if the selected threshold value is undershot.
Note:
F-DO: Failsafe Digital Output / SGA: Safety-related output
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SBR: Safe Brake Ramp (safe brake ramp monitoring)
SSM: Safe Speed Monitor (safety-related feedback signal from the velocity monitoring) / SGA n < nx: Safety-related
output n < nx
p9547
SI Motion SSM (SGA n < nx) velocity hysteresis (CU) / SI Mtn SSM hyst CU
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.0010 [mm/min]
Description:
Sets the velocity hysteresis for the SSM feedback signal to detect standstill (n < nx).
Dependency:
Refer to: C01711
Note:
The velocity hysteresis is effective only if the function is enabled (p9501.16 = 1).
The parameter is included in the crosswise data comparison of the two monitoring channels.
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
p9547
SI Motion SSM (SGA n < nx) velocity hysteresis (CU) / SI Mtn SSM hyst CU
VECTOR_G (Safety
Can be changed: C2(95)
rot)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.0010 [rpm]
Description:
Sets the velocity hysteresis for the SSM feedback signal to detect standstill (n < nx).
Dependency:
Refer to: C01711
Note:
The velocity hysteresis is effective only if the function is enabled (p9501.16 = 1).
The parameter is included in the crosswise data comparison of the two monitoring channels.
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
950
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1000000.00 [rpm]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
500.0000 [mm/min]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
500.0000 [rpm]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 2823
Unit selection: -
Expert list: 1
Factory setting
20.00 [rpm]
Access level: 3
Func. diagram: 2823
Unit selection: -
Expert list: 1
Factory setting
10.0000 [mm/min]
Access level: 3
Func. diagram: 2823
Unit selection: -
Expert list: 1
Factory setting
10.0000 [rpm]