Siemens G130 List Manual page 169

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p0414[0...n]
Redundant coarse position value relevant bits (identified) / Relevant bits
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the number of relevant bits for the redundant coarse position value.
p0415[0...n]
Gx_XIST1 Coarse position safe most significant bit (identified) / Gx_XIST1 safe MSB
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the bit number for the safe most significant bit (MSB) of the Gx_XIST1 coarse position.
Note:
MSB: Most Significant Bit
p0416[0...n]
Non safety-relevant meas. steps position value POS1 (detected) / nsrPos1
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the non safety-relevant measuring steps of POS1.
Dependency:
Refer to: r0473, p9513
p0417[0...n]
Encoder safety comparison algorithm (detected) / Safety comp_algo
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the comparison algorithm for the encoder position monitoring functions.
Value:
0:
10:
11:
12:
255:
Dependency:
Refer to: p9541
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
SMx20 safety algorithm
DQL binary safety algorithm
DQL linear non-binary safety algorithm
SMC30 safety algorithm
Safety algorithm unknown
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
16
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
31
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
4294967295
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
255
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
16
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
14
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
22000
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
255
169