Siemens G130 List Manual page 961

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p9581
SI Motion brake ramp reference value (Control Unit) / SI Mtn ramp ref CU
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
600.0000 [mm/min]
Description:
Sets the reference value to define the brake ramp.
The rate of rise of the brake ramp depends upon p9581 (reference value) and p9583 (monitoring time).
Dependency:
Refer to: p9582, p9583
p9581
SI Motion brake ramp reference value (Control Unit) / SI Mtn ramp ref CU
VECTOR_G (Safety
Can be changed: C2(95)
rot)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
600.0000 [rpm]
Description:
Sets the reference value to define the brake ramp.
The rate of rise of the brake ramp depends upon p9581 (reference value) and p9583 (monitoring time).
Dependency:
Refer to: p9582, p9583
p9582
SI Motion brake ramp delay time (Control Unit) / SI Mtn rp t_del CU
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
10.00 [ms]
Description:
Sets the delay time for monitoring the brake ramp.
Monitoring of the brake ramp starts once the delay time has elapsed.
Dependency:
Refer to: p9581, p9583
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
Internally, the set time is limited downwards to 2 safety monitoring clock cycles (2 * p9500/p9300).
p9583
SI Motion brake ramp monitoring time (Control Unit) / SI Mtn rp t_mon CU
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.50 [s]
Description:
Sets the monitoring time to define the brake ramp.
The rate of rise of the brake ramp depends upon p9581 (reference value) and p9583 (monitoring time).
Dependency:
Refer to: p9581, p9582
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
240000.0000 [mm/min]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
240000.0000 [rpm]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
99000.00 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3600.00 [s]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1500.0000 [mm/min]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1500.0000 [rpm]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
250.00 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
10.00 [s]
961

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents