2 Parameters
2.2 List of parameters
p1601[0...n]
Current injection ramp-up time / I_inject t_ramp-up
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, SESM,
REL
Min
1 [ms]
Description:
The following applies for a synchronous reluctance motor:
Sets the ramp-up time of the current setpoint when switching over from closed-loop controlled operation to open-loop
controlled operation.
The current setpoint is calculated from p1610 and p1611.
r1602
CO: P flux controller output / P flux ctrl outp
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, REL
Min
- [Arms]
Description:
Displays the output of the P flux controller for separately excited synchronous motors (SESM).
p1604[0...n]
Pulse technique current limit / Pulse current lim
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, SESM, REL
Min
0.00 [Arms]
Description:
Sets the effective current limit within the pulse technique.
Note:
The saturation characteristic of the motor defines the available operating range for the pulse technique.
This operating range can be adjusted using the current limit.
When commissioning a catalog motor, the technique is automatically selected depending on the motor type being
used.
Otherwise, the rated motor current is used as pre-assigned value.
p1605[0...n]
Pulse technique pattern configuration / Puls pattrn config
VECTOR_G (n/M)
Can be changed: U, T
Data type: Integer16
P-Group: Closed-loop control
Not for motor type: ASM, SESM, REL
Min
1
Description:
Sets the applied pulse patterns for estimating the continuous rotor position.
Remark:
See p1750 for the activation of the pulse-pattern technique.
Value:
1:
2:
Dependency:
Refer to: p1750
Note:
When commissioning a catalog motor, the technique is automatically selected depending on the motor type being
used.
424
pm
ppmm
Calculated: CALC_MOD_REG
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000.00 [Arms]
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
2
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 6790
Unit selection: -
Expert list: 1
Factory setting
20 [ms]
Access level: 4
Func. diagram: 6726, 6727
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [Arms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents