2 Parameters
2.2 List of parameters
r0837.0...4
CO/BO: Drive Data Set DDS selected / DDS selected
VECTOR_G, ENC
Can be changed: -
Data type: Unsigned8
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the drive data set (DDS) selected via the binector input.
Bit field:
Bit
00
01
02
03
04
Dependency:
Refer to: r0051, p0820, p0821, p0822, p0823, p0824
Note:
Drive data sets are selected via binector input p0820 and following.
The currently effective drive data set is displayed in r0051.
If there is only one data set, then a value of 0 is displayed in this parameter and not the selection via binector inputs.
r0838[0...3]
Motor/Encoder Data Set selected / MDS/EDS selected
VECTOR_G
Can be changed: -
Data type: Unsigned8
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the selected Motor Data Set (MDS) and the selected Encoder Data Sets (EDS).
Index:
[0] = Motor Data Set MDS selected
[1] = Encoder 1 Encoder Data Set EDS selected
[2] = Encoder 2 Encoder Data Set EDS selected
[3] = Encoder 3 Encoder Data Set EDS selected
Dependency:
Refer to: r0049, p0186, p0187, p0188, p0189
Note:
Value 99 means the following: No encoder assigned (not configured).
p0839
Motor changeover contactor control delay time / Mot_chg ctrl t_del
VECTOR_G
Can be changed: C2(3)
Data type: Unsigned16
P-Group: Motor
Not for motor type: -
Min
0 [ms]
Description:
Sets the delay time for the contactor control for the motor changeover.
Note:
The delay time is taken into account in the following cases:
- for feedback signal, previous contactor "Open". The new motor contactor is controlled (energized) after the delay
time has expired.
- for the feedback signal, new motor contactor "Closed". The pulses are enabled after the delay time has expired.
274
Signal name
DDS select. bit 0
DDS select. bit 1
DDS select. bit 2
DDS select. bit 3
DDS select. bit 4
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
ON
ON
ON
ON
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
500 [ms]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: 8565
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF
OFF
OFF
OFF
OFF
Access level: 2
Func. diagram: 8565
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
SINAMICS G130/G150
FP
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents