p4068[0...1]
TB30 analog inputs noise suppression window / TB30 AI window
TB30
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
0.00 [%]
Description:
Sets the noise suppression window of the analog inputs for Terminal Board 30 (TB30).
Changes less than the window are suppressed.
Index:
[0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
Note:
AI: Analog Input
p4069[0...1]
BI: TM31 analog inputs signal source for enable / TM31 AI enable
TM31
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: Terminals
Not for motor type: -
Min
-
Description:
Sets the signal source for the enable signal of the analog inputs of Terminal Module 31 (TM31).
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
p4069[0...1]
BI: TB30 analog inputs signal source for enable / TB30 AI enable
TB30
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: Terminals
Not for motor type: -
Min
-
Description:
Sets the signal source for enabling the analog inputs of the Terminal Board 30 (TB30).
Index:
[0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
p4071[0...1]
CI: TM31 analog outputs signal source / TM31 AO s_src
TM31
Can be changed: U, T
Data type: Unsigned32 / FloatingPoint32
P-Group: Terminals
Not for motor type: -
Min
-
Description:
Sets the signal source for the analog outputs of Terminal Module 31 (TM31).
Index:
[0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Note:
AO: Analog Output
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
20.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 9104
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 3
Func. diagram: 9566, 9568
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 9104
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 1
Func. diagram: 9549, 9572
Unit selection: -
Expert list: 1
Factory setting
0