Siemens G130 List Manual page 687

Hide thumbs Also See for G130:
Table of Contents

Advertisement

Note:
Value = 999 means:
- the component specified in p4650 is not connected
- the encoder does not support the display of the functional reserve
p4652[0...2]
XIST1_ERW reset mode / XIST1_ERW res mode
VECTOR_G
Can be changed: C1(3)
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the mode to reset the actual value in XIST_ERW (CO: r4653).
Value:
0:
1:
2:
3:
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: r4653, r4654, p4655
Note:
The absolute value is only valid after passing the zero mark.
If value = 1:
The value in XIST1_ERW is reset when passing every zero mark.
If value = 2:
The value in XIST1_ERW is reset with a 0/1 edge via binector input p4655.
If value = 3:
The value in XIST1_ERW is reset after a 0/1 edge via binector input p4655 when passing the next zero mark.
p4652
XIST1_ERW reset mode / XIST1_ERW res mode
ENC
Can be changed: C1(3)
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the mode to reset the actual value in XIST_ERW (CO: r4653).
Value:
0:
1:
2:
3:
Dependency:
Refer to: r4653, r4654, p4655
Note:
The absolute value is only valid after passing the zero mark.
If value = 1:
The value in XIST1_ERW is reset when passing every zero mark.
If value = 2:
The value in XIST1_ERW is reset with a 0/1 edge via binector input p4655.
If value = 3:
The value in XIST1_ERW is reset after a 0/1 edge via binector input p4655 when passing the next zero mark.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Inactive
Reset with zero mark
Reset with BICO
Reset with selected zero mark
Inactive
Reset with zero mark
Reset with BICO
Reset with selected zero mark
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 4750
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 4750
Unit selection: -
Expert list: 1
Factory setting
0