p4688[0...2]
CO: Zero mark monitoring differential pulse count / ZM diff_pulse qty
VECTOR_G
Can be changed: T
Data type: Integer32
P-Group: -
Not for motor type: -
Min
-2147483648
Description:
Display and connector output for the identified incorrect pulses in lines.
Also see p0437.7 (do not accumulate number of incorrect pulses).
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p0437, p4681, p4682, p4683, p4684
Note:
The display can only be reset to zero.
p4688
CO: Zero mark monitoring differential pulse count / ZM diff_pulse qty
ENC
Can be changed: T
Data type: Integer32
P-Group: -
Not for motor type: -
Min
-2147483648
Description:
Display and connector output for the identified incorrect pulses in lines.
Also see p0437.7 (do not accumulate number of incorrect pulses).
Dependency:
Refer to: p0437, p4681, p4682, p4683, p4684
Note:
The display can only be reset to zero.
r4689[0...2]
CO: Squarewave encoder diagnostics / Sq-wave enc diag
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the encoder status according to PROFIdrive for a squarewave encoder.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: A31422
Note:
After alarm A3x422 is output, this parameter is set for 100 ms.
r4689
CO: Squarewave encoder diagnostics / Sq-wave enc diag
ENC
Can be changed: -
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the encoder status according to PROFIdrive for a squarewave encoder.
Dependency:
Refer to: A31422
Note:
After alarm A3x422 is output, this parameter is set for 100 ms.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2147483647
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2147483647
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-