2 Parameters
2.2 List of parameters
r1809
CO: Modulator mode actual / Modulator mode act
VECTOR_G
Can be changed: -
Data type: Integer16
P-Group: Modulation
Not for motor type: -
Min
1
Description:
Displays the effective modulator mode.
Value:
1:
2:
3:
4:
5:
6:
7:
8:
9:
p1810
Modulator configuration / Modulator config
VECTOR_G
Can be changed: U, T
Data type: Unsigned16
P-Group: Modulation
Not for motor type: -
Min
-
Description:
Sets the configuration for the modulator.
Bit field:
Bit
00
01
02
03
08
09
10
12
13
14
15
Dependency:
If bit 2 is set from 1 to 0, p1811 = 0 is set.
Notice:
Bit 1 = 0 can only be set under a pulse inhibit and for r0192.14 = 1.
Bit 2 can only be set to 1 subject to the following prerequisites:
- Pulse inhibit
- r0192.16 = 1
- p1800 < 2 x 1000/p0115[0]
462
Flat top modulation (FLB)
Space vector modulation (SVM)
Edge modulation from 28 Hz; 23:3
Edge modulation from 28 Hz; 19:1
Edge modulation from 60 Hz; 17:3
Edge modulation from 60 Hz; 17:1
Edge modulation from 100 Hz; 9:2
Edge modulation from 100 Hz; 9:1
Optimized pulse pattern
Signal name
Avg value filter for V_lim (only for
Vdc_comp in modulator)
DC link voltage compensation in the current
control
Wobbulation activated
Current measurement oversampling
selected
Pulse frequency reduction (speed
dependent) stage 1
Pulse frequency reduction (speed
dependent) stage 2
Activate pulse-locking/pulse-dropping
function
Pulse freq. can be asynchronously set to
curr. ctrl clock cycle
Pulse freq. reduction before optimized pulse
patterns for 500 µs
Deactivate maximum angular difference
adaptation
Increase overmodulation range
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
9
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Pulse-Dropping
Yes
Yes
Yes
Yes
List Manual (LH2), 07/2016, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0010 bin
0 signal
No
No
No
No
No
No
Pulse-Locking
No
No
No
No
SINAMICS G130/G150