2 Parameters
2.2 List of parameters
r3841
CO: Friction characteristic output / Frict outp
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: REL
Min
- [Nm]
Description:
Display and connector output for the torque of the friction characteristic dependent on the speed.
Dependency:
Refer to: p1569, p3842
p3842
Friction characteristic activation / Frict act
VECTOR_G (n/M)
Can be changed: T
Data type: Integer16
P-Group: Functions
Not for motor type: REL
Min
0
Description:
Setting to activate and deactivate the friction characteristic.
Value:
0:
1:
Dependency:
Refer to: p1569, r3841, p3845
p3843[0...n]
Friction characteristic frictional torque diff. smoothing time / Frict M_diff t_sm
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: PMSM, SESM, REL
Min
0.00 [ms]
Description:
Sets the smoothing time constant (PT1) for the friction torque difference.
Smoothing is activated when switching over from status bit r3840.9.
Dependency:
Refer to: p3844
p3844[0...n]
Friction characteristic number changeover point upper / FricNo chng_pt up
VECTOR_G (n/M)
Can be changed: U, T
Data type: Unsigned8
P-Group: Closed-loop control
Not for motor type: PMSM, SESM, REL
Min
0
Description:
Selects the upper changeover point of the friction characteristic for the frictional torque input controlled by the motor
model of the induction motor.
The speed of this changeover point is pre-assigned when automatically calculating with the changeover speed
p1752. The changeover point located below is pre-assigned with the changeover speed p1752 * (1 - p1753).
Example:
p3844 = 3 means that the speed value for the change to the monitor model (p3823 = p1752) is entered into p3823
(friction characteristic value n3).
Depending on the display of r3840.9, the frictional torque is calculated from the friction characteristic values, which
are associated with these changeover points. For the changeover of the motor model, with hysteresis, the frictional
torque smoothed with p3843 changes between these two states.
Dependency:
As part of the automatic calculation (p0340), p3844 is only activated for closed loop control (p1300 = 21, 23) of
induction motors with encoder.
Refer to: p3843
626
Friction characteristic deactivated
Friction characteristic activated
Calculated: -
Dyn. index: -
Unit group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000.00 [ms]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
4
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 2
Func. diagram: 7010
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0