r0297
DC link voltage overvoltage threshold / Vdc U_upper_thresh
VECTOR_G, B_INF
Can be changed: -
Data type: Unsigned16
P-Group: Converter
Not for motor type: -
Min
- [V]
Description:
Threshold to detect a DC link overvoltage.
If the DC link voltage exceeds the threshold specified here, the drive unit is tripped due to DC link overvoltage.
Dependency:
Refer to: F30002
p0300[0...n]
Motor type selection / Mot type sel
VECTOR_G
Can be changed: C2(1, 3)
Data type: Integer16
P-Group: Motor
Not for motor type: -
Min
0
Description:
Selects the motor type or starts to read in the motor parameters for a motor with DRIVE-CLiQ (p0300 = 10000 or
10001, if there is a second data set).
For p0300 < 10000 the following applies:
The first digit of the parameter value always defines the general motor type and corresponds to the third-party motor
belonging to a motor list:
1 = induction motor
2 = synchronous motor
5 = synchronous motor separately excited
7 = SIEMOSYN motor
8 = reluctance motor (for textile applications)
xx = motor without code number
xxx = motor with code number
The type information must be entered to filter motor-specific parameters and to optimize the operating characteristics
and behavior. For example, for synchronous motors, power factor (p0308) is neither used nor displayed (in the
BOP/AOP).
The following applies for values < 100:
Motor data must be manually entered.
The following applies for values >= 100:
Motor data are automatically loaded from an internal list.
Value:
0:
1:
2:
6:
7:
8:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
100:
101:
102:
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
No motor
Induction motor
Synchronous motor
Synchronous reluctance motor
SIEMOSYN synchronous motor
Reluctance motor textile
1LE1 induction motor (not a code number)
1LA1 induction motor (not a code number)
1LE2 induction motor (not a code number)
1LG6 induction motor (not a code number)
1xx1 SIMOTICS FD induction motor (not a code number)
1LA5 induction motor (not a code number)
1LA6 induction motor (not a code number)
1LA7 induction motor (not a code number)
1xx8 SIMOTICS TN induction motor (not a code number)
1LA9 induction motor (not a code number)
1LE1 induction motor
1PC1 induction motor
1PH2 induction motor
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [V]
Calculated: -
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
10001
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8750, 8760,
8850, 8864, 8950, 8964
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 1
Func. diagram: 6310
Unit selection: -
Expert list: 1
Factory setting
0