Siemens G130 List Manual page 160

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p0397[0...n]
Angle magnetic decoupling maximum angle / Magn decpl max_ang
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, SESM, REL,
RESM
Min
0.0 [°]
Description:
Maximum angle when calculating the polynomial function to decouple the magnetic flux axes for permanent-magnet
synchronous motors (see p0398, p0399).
p0398[0...n]
Angle magn decoupling (cross saturation) coeff 1 / Magn decoupl C1
VECTOR_G
Can be changed: C2(3), U, T
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, SESM, REL,
RESM
Min
-10.000000
Description:
The magnetic cross coupling of the motor's d and q axes caused by saturation (current-dependent) leads to an angle
offset affecting the axis system d'q'; this decouples the magnetic quantities.
The angle offset can be described as a 3rd order polynomial function of the load current consumed:
phiOffset = f(C1*iq + C3*iq^3)
This parameter is the coefficient C1; it describes the linear load impact effect.
p0399[0...n]
Angle magn decoupling (cross saturation) coeff 3 / Magn decoupl C3
VECTOR_G
Can be changed: C2(3), U, T
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, SESM, REL,
RESM
Min
-10.000000
Description:
The magnetic cross coupling of the motor's d and q axes caused by saturation (current-dependent) leads to an angle
offset affecting the axis system d'q'; this decouples the magnetic quantities.
The angle offset can be described as a 3rd order polynomial function of the load current consumed:
phiOffset = f(C1*iq + C3*iq^3)
This parameter is the coefficient C3; it describes the cubic load impact effect.
p0400[0...n]
Encoder type selection / Enc_typ sel
VECTOR_G
Can be changed: C2(1, 4)
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Selects the encoder from the list of encoder types supported.
Value:
0:
3001: 1024 HTL A/B R
3002: 1024 TTL A/B R
3003: 2048 HTL A/B R
3005: 1024 HTL A/B
3006: 1024 TTL A/B
3007: 2048 HTL A/B
160
No encoder
Calculated: CALC_MOD_EQU
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
90.0 [°]
Calculated: CALC_MOD_EQU
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
10.000000
Calculated: CALC_MOD_EQU
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
10.000000
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
10000
List Manual (LH2), 07/2016, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
90.0 [°]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.000000
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.000000
Access level: 1
Func. diagram: 4700, 4704
Unit selection: -
Expert list: 1
Factory setting
0