r2349.0...13
CO/BO: Technology controller status word / Tec_ctrl ZSW
VECTOR_G
Can be changed: -
(Tech_ctrl)
Data type: Unsigned32
P-Group: Technology
Not for motor type: -
Min
-
Description:
Display and BICO output for the status word of the technology controller.
Bit field:
Bit
00
01
02
03
04
05
06
08
09
10
11
12
13
p2369
BI: Closed-loop cascade control, control word / Csc_ctrl STW
VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the selection of the "Switch-in motor" function.
When the function is selected, monitoring of the switches is deactivated with the "bypass" function. This means that
the power unit can be connected to other motors via an external control without switch monitoring responding.
r2700
CO: Reference speed/reference frequency / n_ref/f_ref
VECTOR_G, ENC
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output for the reference quantity for speed and frequency (p2000).
All speeds or frequencies specified as relative value are referred to this reference quantity.
The reference quantity corresponds to 100% or 4000 hex (word) or 4000 0000 hex (double word).
This parameter has the unit rpm.
The following applies:
Reference frequency (in Hz) = reference speed (in rpm) / 60
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Technology controller deactivated
Technology controller limited
Technology controller motorized
potentiometer limited max
Technology controller motorized
potentiometer limited min
Technology controller speed setpoint total in
setpoint channel
Technology controller RFG bypassed in the
setpoint channel
Technology controller starting value at the
current limit
Technology controller actual value at the
minimum
Technology controller actual value at the
maximum
Technology controller output at the
minimum
Technology controller output at the
maximum
Fault response active
Technology controller limiting enable
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
Yes
No
No
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
579