2 Parameters
2.2 List of parameters
p9550
SI Motion SGE changeover tolerance time (Control Unit) / SI Mtn SGE chg tol
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the tolerance time for the changeover of the safety-related inputs (SGE).
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
p9551
SI Motion SLS(SG) changeover/SOS (SBH) delay time (CU) / SI SLS/SOS t CU
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the delay time for the SLS changeover and for the activation of SOS for the functions "Safely Limited Speed"
(SLS) and "Safe Operating Stop" (SOS).
When transitioning from a higher to a lower safely limited speed level, and when activating safe operating stop
(SOS), within this delay time, the "old" speed level remains active.
This delay is also applicable when activating SLS from the state "SOS and SLS inactive" and activating SOS from the
state "SOS inactive".
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SLS: Safely Limited Speed / SG: Safely reduced speed
SOS: Safe Operating Stop / SBH: Safe operating stop
p9552
SI Motion transition time STOP C to SOS (SBH) (Control Unit) / SI Mtn t C->SOS CU
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the transition time from STOP C to "Safe Operating Stop" (SOS).
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SOS: Safe Operating Stop / SBH: Safe operating stop
p9553
SI Motion transition time STOP D to SOS (SBH) (Control Unit) / SI Mtn t D->SOS CU
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the transition time from STOP D to "Safe Operating Stop" (SOS).
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SOS: Safe Operating Stop / SBH: Safe operating stop
952
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000.00 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
600000.00 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
600000.00 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
600000.00 [ms]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
500.00 [ms]
Access level: 3
Func. diagram: 2819, 2820
Unit selection: -
Expert list: 1
Factory setting
100.00 [ms]
Access level: 3
Func. diagram: 2819
Unit selection: -
Expert list: 1
Factory setting
100.00 [ms]
Access level: 3
Func. diagram: 2819
Unit selection: -
Expert list: 1
Factory setting
100.00 [ms]