Siemens G130 List Manual page 764

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r7224[0...n]
CO: Par_circuit phase current actual value phase V / I_phase V act val
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the measured actual value of phase V as peak value.
The summed value of all power units is displayed in r0069[1].
r7225[0...n]
CO: Par_circuit phase current actual value phase W / I_phase W act val
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the measured actual value of phase W as peak value.
The summed value of all power units is displayed in r0069[2].
r7226[0...n]
CO: Par_circuit phase current actual value phase U offset / I_phase U offset
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the measured offset of phase U as peak value.
The summed value of all power units is displayed in r0069[3].
r7227[0...n]
CO: Par_circuit phase current actual value phase V offset / I_phase V offset
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the measured offset of phase V as peak value.
The summed value of all power units is displayed in r0069[4].
r7228[0...n]
CO: Par_circuit phase current actual value phase W offset / I_phase W offset
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the measured offset of phase W as peak value.
The summed value of all power units is displayed in r0069[5].
764
Calculated: -
Dyn. index: PDS, p0120
Unit group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: PDS, p0120
Unit group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: PDS, p0120
Unit group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: PDS, p0120
Unit group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: PDS, p0120
Unit group: 6_5
Scaling: p2002
Max
- [A]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents