Siemens G130 List Manual page 754

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r7021[0...n]
CO: Par_circuit deviation current in phase V / Phase V curr dev
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the deviation between the measured current actual value of phase V and the average value as peak value.
The maximum deviation from the average value is displayed in r7026.
Dependency:
Refer to: r7020, r7022, r7026
r7022[0...n]
CO: Par_circuit deviation current in phase W / Phase W curr dev
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the deviation between the measured current actual value of phase W and the average value as peak value.
The maximum deviation from the average value is displayed in r7027.
Dependency:
Refer to: r7020, r7021, r7027
r7025
CO: Par_circuit max. deviation currents phase U / Phase U Max i_dev
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the maximum absolute deviation of the measured current actual values of phase U from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7020.
Dependency:
Refer to: r7020, r7026, r7027
Refer to: A05052
r7026
CO: Par_circuit max. deviation currents phase V / Phase V Max i_dev
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the maximum absolute deviation of the measured current actual values of phase V from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7021.
Dependency:
Refer to: r7021, r7025, r7027
Refer to: A05052
754
Calculated: -
Dyn. index: PDS, p0120
Unit group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: PDS, p0120
Unit group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: -
Unit group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: -
Unit group: 6_5
Scaling: p2002
Max
- [A]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents