Scc Uart Event Register (Scce) And Mask Register (Sccm) - Freescale Semiconductor MPC850 User Manual

Mpc850 family integrated communications microprocessor
Table of Contents

Advertisement

SCC UART Event Register (SCCE) and Mask Register (SCCM)

Table 22-11. SCC UART TxBD Status and Control Field Descriptions (Continued)
Bit
Name
4
CR
Clear-to-send report.
0 The next buffer is sent with no delay (assuming it is ready), but if a CTS lost condition occurs,
TxBD[CT] may not be set in the correct TxBD or may not be set at all. Asynchronous flow control,
however, continues to function normally.
1 Normal CTS lost error reporting and three bits of idle are sent between consecutive buffers.
5
A
Address. Valid only in multidrop mode—automatic or manual.
0 This buffer contains only data.
1 This buffer contains address characters. All data in this buffer is sent as address characters.
CM
6
Continuous mode.
0 Normal operation. The CPM clears R after this BD is closed.
1 The CPM does not clear R after this BD is closed, allowing the buffer to be resent next time the
CPM accesses this BD. However, R is cleared by transmission errors, regardless of CM.
P
7
Preamble.
0 No preamble sequence is sent.
1 Before sending data, the controller sends an idle character consisting of all ones. If the data length
of this BD is zero, only a preamble is sent.
8
NS
No stop bit or shaved stop bit sent.
0 Normal operation. Stop bits are sent with all characters in this buffer.
1 If PSMR[SYN] = 1, data in this buffer is sent without stop bits. If SYN = 0, the stop bit is shaved,
depending on the DSR setting; see Section 22.14, "Fractional Stop Bits (Transmitter)."
9–1
Reserved, should be cleared.
4
15
CT
CTS lost. The CPM writes this status bit after sending the associated buffer.
0 CTS remained asserted during transmission.
1 CTS negated during transmission.
The data length and buffer pointer fields are described in Section 21.3, "SCC Buffer
Descriptors (BDs)."
22.19 SCC UART Event Register (SCCE) and Mask
Register (SCCM)
The SCC event register (SCCE) is used to report events recognized by the UART channel
and to generate interrupts. When an event is recognized, the controller sets the
corresponding SCCE bit. Interrupts can be masked in the UART mask register (SCCM),
which has the same format as SCCE. Setting a mask bit enables the corresponding SCCE
interrupt; clearing a bit masks it. Figure 22-10 shows example interrupts that can be
generated by the SCC UART controller.
Description
MPC850 Family User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpc850deMpc850dslMpc850sr

Table of Contents