Operating manual
GMK4100L-1
Accept the measured outrigger span
Select and confirm – the outrigger span provided by the outrigger width
monitoring is adopted and shown on the Enter outrigger span display;
à
Confirm the rigging mode and lifting capacity table , p. 11 - 41.
9.2 Short description of the operating elements
Enter outrigger span
( MAXbase )
The values are entered individually for outrig-
ger beams (1) to (4).
In input mode – select and confirm the indi-
vidual widths.
Outrigger span monitoring display
( MAXbase )
5 Measured outrigger width = required
width
6 Measured outrigger width ≠ of required
width
à
Enter rigging mode , p. 11 - 32
Enter outrigger span
( Standard )
The selection occurs simultaneously for all
outrigger beams – selected outrigger widths
are orange.
In input mode – select and confirm the outrig-
ger span
1 8.660 x 7.200 m (28.4 x 23.6 ft)
2 8.660 x 6.250 m (28.4 x 20.5 ft)
3 8.660 x 5.300 m (28.4 x 17.4 ft)
4 8.660 x 3.800 m (28.4 x 12.4 ft)
5 8.660 x 2.340 m (28.4 x 7.6 ft)
à
Enter rigging mode , p. 11 - 32