Manuals and User Guides for Siemens LMV51 Series. We have
3
Siemens LMV51 Series manuals available for free PDF download: Basic Documentation, Manual
Siemens LMV51 Series Basic Documentation (299 pages)
Burner Control with integrated Fuel / Air Ratio Control and Load Control, Load Control including O2 Trim Control for Forced Draft Burners
Brand:
Siemens
| Category:
Control Unit
| Size: 5.36 MB
Table of Contents
4
Table of Contents
23
Lmv51.140B1
23
Lmv51.200A1
23
Lmv51.200A2
23
Lmv52.200A1
23
Lmv52.200A2
23
Lmv52.240A1
24
Block Diagram Inputs / Outputs
25
Block Diagram (Cont'D)
26
Block Diagram (Cont'D)
27
Fuel Train Applications (Examples)
27
Direct Gas Ignition
27
Gas Pilot Ignition 1
27
Gas Pilot Ignition 2
27
Fuel Valve Control Program
28
Fuel Train Applications (Cont'D)
28
Direct Ignition with Light Oil, Multistage
29
Direct Ignition with Light Oil, Modulating
29
Fuel Valve Control Program
30
Direct Ignition with Heavy Oil, Multistage
30
Direct Ignition with Heavy Oil, Modulating
31
Fuel Valve Control Program
32
Dual-Fuel Burner Gas / Light Oil with Gas Pilot Ignition
32
Fuel Valve Control Program
33
Dual-Fuel Burner Gas / Heavy Oil with Gas Pilot Ignition
33
Fuel Valve Control Program
34
Burner Control
34
Description of Inputs and Outputs
34
Flame Signal Input and Flame Detector X10-01 and X10-03
34
Self-Test Function LMV5
34
Separate Flame Supervision, Only with LMV52
35
Application Example
35
Implementation
35
Technical Data, Flame Supervision
35
QRI (Suited for Continuous Operation)
35
Connection Diagram
36
IONIZATION (Suited for Continuous Operation)
36
Qrb
37
Digital Inputs
37
Safety Loop X3-04
37
Flange X3-03
37
Inputs for External Controller (ON/OFF) X5-03
38
Inputs (ON / OFF or STAGE2 / STAGE3)
38
X5-03
38
Air Pressure Switch (APS) X3-02
39
Pressure Switch-Vp-Gas / LT or Closed Position Indicator (CPI) X9-03
39
Pressure Switch-Min-Gas, Start Release Gas (Psmin-Gas) X9-03
40
Start Release Gas X7-03 (Only with LMV52
40
Pressure Switch-Max-Gas, (Psmax-Gas) X9-03
40
Pressure Switch-Min-Oil (Psmin-Oil) X5-01
41
Direct Heavy Oil Start (HO-START) X6-01
41
Fan Contactor Contact (FCC) or FGR-PS X4-01
41
Pressure Switch-Max-Oil (Psmax-Oil) X5-02
41
Start Release-Oil (START) X6-01
42
Alarm Output, Type No-Si X3-01
42
Digital Outputs
42
Output Fan, Type No-Si X3-01
42
Output Ignition, Type SI (IGNITION) X4-02
42
Outputs Valves -Gas, Type SI (V
42
Outputs Valves-Oil , Type SI (V
43
(Start) X4-03
43
Output Oil Pump / Magnetic Clutch, Type No-Si X6-02
44
Parameters
44
Program Sequence
44
Time Parameters
45
Gas Valve Proving
45
Recommendation
46
Determination of VP Leakage Rate
47
Lockout Phase (Phase 00)
47
Reset / Manual Lockout
47
Characteristics
47
Safety Phase (Phase 01)
47
Special Functions During the Program Sequence
48
Forced Intermittent Operation
48
Program Stop Function
48
Signaling Star Preventions
49
Gas Shortage Program
49
Sequence Diagram
49
Part Load Shutdown
50
Continuous Fan Operation
50
Continuous Pilot Control (Only LMV52)
50
Normal / Direct Start
50
Response to Extraneous Light in Standby
51
Fuel Changeover
51
Selection of Fuel
51
Selection of Fuel On the AZL5
51
Selection of Fuel Via BACS
51
Selection of Fuel with the Fuel Selector On the LMV5
52
Direct Gas Ignition
52
Sequence Diagrams
53
Gas Pilot Ignition 1
54
Gas Pilot Ignition 2
55
Light Oil Direct Ignition
56
Heavy Oil Direct Ignition
57
Light Oil with Gas Pilot Ignition
58
Heavy Oil with Gas Pilot Ignition
59
Legend to the Sequence Diagrams
60
Basic Documentation LMV5
60
Fuel / Air Ratio Control (FARC)
60
General
60
Program Sequence
60
Standby
61
End of Operating Position
61
Ignition
61
Operation
61
Traveling to the Operating Position
62
Actuator Speed Outside Normal Operation
62
Operating Position
62
Modulating
63
Multistage Operation
62
Postpurging
64
Dynamic Safety Time Ratio Control
64
Position Check
66
Direction of Rotation of Actuators
66
Operating Position Modulating
66
Operating Position Multistage
66
Outside the Operating Position
66
Program Stop
66
Special Features
67
Limitation of the Load Range
68
Activation of Actuators / VSD
68
Lmv51
68
Lmv52
68
Number of Fuel Actuators
68
Shutdown Behavior
68
Traveling Times
69
Connection Diagram
69
General
69
Operating Modes with the Load Controller
69
Temperature or Pressure Controller (Internal Load Controller LC)
70
Operating Mode 1 (Extlc X5-03)
71
Operating Mode 2 (Intlc)
71
Operating Mode 3 (Int LC Bus)
72
Operating Mode 4 (Int LC X62)
72
Operating Mode 5 (Ext LC X62)
73
Operating Mode 6 (Ext LC Bus)
73
Operating Mode Changeover to Internal Load Controller
74
Control (Characteristics)
74
General
74
Switching Differentials
74
Integrated 2-Position Controller (C = ON / OFF)
74
Operating Mode
75
Control Parameters
75
Manual Setting of the Control Parameters
75
Function Diagrams
75
General
75
Modulating Control
76
Adaption Sequence
76
Self-Setting of Control Parameters (Adaption)
77
Checking the Control Parameters
77
Example
78
Settling of the Manipulated Variable
78
Principle
78
Description (Graph)
79
General
79
Load-Dependent Activation of the Higher Burner Stages
79
Multistage Control
80
Function Diagrams
81
Actual Values (X)
81
Input 1, TEMP, Pt100 Sensor (DIN) X60
81
Input 2: TEMP. / PRESS INPUT, DC 0
81
X61
81
Measuring Range Temperature (Can Be Parameterized)
81
Measuring Range Pressure (Can Be Parameterized)
82
Input 4: TEMP, Pt1000 / Lg-Ni 1000 X60
83
Input 3: SET POINT INPUT X62
83
External Predefined Setpoint
83
External Predefined Load
83
External Predefined Load, Modulating
84
External Predefined Load, Multistage
84
External Setpoint Changeover
83
Internal Setpoint
83
Setpoints (W)
84
External Setpoints or Predefined Load Via Digital Modbus / E-Bus Interface
85
Integrated Temperature Limiter Function
85
Requirements Placed On Sensor and Protection Pocket
85
TL with External Predefined Load
85
TL Within the Scope of TRD
86
Cold Start Thermal Shock Protection (CSTP)
86
CSTP - Modulating Operation
87
CSTP - Multistage Operation
87
CSTP with Temperature Sensor in Pressure Plants
88
Multiboiler Plants
88
Multiboiler Plants By Means of an Analog Input
88
Output
88
Output 4
88
Output, Modulating
88
Output, Multistage
89
Display and Operating Unit AZL5
90
Assignment of AZL5
91
Connecting Cable to the E-Bus Adapter
91
Connecting Cable to the PC
92
Ports of the AZL5
93
Port for the PC
94
Connection to Superposed Systems
94
General Information and BACS Functions
94
Reading Ebus-Specific
94
Data
95
Writing Parameters
95
List of Supported Ebus Commands
96
Display and Settings
96
Menu Structure
97
Displays
98
Display (Cont'D)
99
Displays (Cont'D)
100
Lockout and Error Messages
101
Lockout and Error Messages (Cont'D)
102
Standard Parameterizations (Incl. Entry of Password)
103
Entry of Password (PW)
103
Start Display
104
First Submenu Level
104
Second Submenu Level
104
Third Submenu Level
104
Fourth Submenu Level
105
Addressing the Actuators (Function Assignment)
106
Direction of Rotation
106
Reset
106
Operational Status Indication By LED On the Actuator
106
Power Is Fed to Unaddressed Actuator
106
Button for Addressing Is Pressed (Display During Addressing Procedure)
106
Addressing Completed, Normal Operation of Actuator
107
Special Function Curve Settings FARC
117
Special Function Adaption LC
119
Burner Identification (Burner ID)
119
Makeup of Burner ID
119
Languages
119
Real Time Clock and Calendar
119
S / W Changeover
119
Backup
120
Adjustment of Contrast (Display)
120
Quick Access Normal Operation
120
Shutdown Function
121
Azl5
121
Loss-Of-Flame Test
121
Menu and Parameter Lists
121
Safety Check Function
121
SLT Test
150
Basic Configuration
150
Commissioning Instructions for the LMV5
150
Parameterizing the Burner Identification (Burner ID)
150
Practice-Oriented Setting Instructions for the System Configuration, the Burner Control, and the Electronic Fuel / Air Ratio Control System
150
Selecting the Fuel Trains
150
Checking the Inputs / Outputs While Taking Into Account the Burner
151
Setting Gas Valve Proving
151
Addressing the Actuators
152
Selecting the Actuator's Direction of Rotation
152
Configuration of VSD (Only Lmv5X.2
152
Lmv52
153
Setting the Load Controller (Option)
153
Selecting a Temperature or Pressure Sensor
154
Settings for Gas-Fired Operation
154
Activating Program Stops in Different Program Phases
154
Checking and Presetting the Actuators Positions for Gas Ignition
154
Manual Startup
155
Actuator Positions During the Prepurge Time
155
Note
155
Ignition Positions
156
Setting the Curve
156
First Setting
157
Changing an Existing Curve
157
Creating a New Curvepoint
157
Loadlimits
157
Shutdown
158
Settings for Multistage Firing On Oil
158
Fuel Changeover for Firing On Oil
158
Changing the Burner Operating Mode From Modulating to Multistage (Only When Firing On Oil)
158
Activating the Program Stops in the Different Program Phases
159
Checking and Presetting the Ignition Positions for Firing On Oil
159
Manual Startup
159
Actuator Positions During the Prepurge Time
159
Note
160
Ignition Positions
161
Setting the Burner Stages
162
Shutdown
163
Extra Functions of the LMV5
163
Valve Proving (Leakage Test LT)
164
Example 1 (Calculation of Test Time)
164
Example 2 (Determination of Detectable Leakage Rate)
165
Configuration of the Load Controller
165
Selection of Operating Mode
166
Control Parameters of the Load Controller
166
Selection of the Standard Parameter Set
166
Individual Setting of the PID Parameters
166
Automatic Adaption
167
Temperature Limiter Function
167
Boiler Setpoints W1 and W2
168
2-Position Controller (C = ON / OFF)
168
Diagram
168
Cold Start Thermal Shock Protection (CSTP)
168
Description
170
Connection Terminals / Coding of Connectors
170
Connection Terminals of the Lmv51.000X1 / Lmv51.040X1
171
Connection Terminals of the Lmv51.000X2
172
Connection Terminals of the Lmv51.100X1 / Lmv51.140X1
173
Connection Terminals of the Lmv51.100X2
174
Connection Terminals of the Lmv51.200X1
175
Connection Terminals of the Lmv51.200X2
176
Connection Terminals of the LMV52.200A2 / LMV52.240A2
177
Connection Terminals of the LMV52.200A1 / LMV52.240A1
178
Coding of Connectors
179
Agg5.720
180
Agg5.721
181
Description of the Connection Terminals (AC 120 V)
186
Description of the Connection Terminals (AC 230 V)
191
Connection of LMV5
191
Electrical Connections and Wiring
191
Installation
191
Mounting, Electrical Installation and Service
192
Power Supply to the LMV5
195
Determination of the Maximum Cable Length
196
Types of Cable
197
E-Bus / PC Adapter Part No. 230 437
197
Mounting Rail Adapter Type: USA 10 / 4,6
197
Suppliers of Other Accessory Items
198
Correct Parameterization of the System
198
Duties of the Authorized Inspector
198
Lmv51
198
In Addition with LMV52
199
Burner Control Section
199
Fuel / Air Ratio Control System
200
General
200
O2 Trim Control (Only with LMV52
201
Basic Unit LMV5
201
Environmental Conditions LMV5
201
Azl
201
Environmental Conditions AZL5
201
Lmv5
201
Technical Data
202
Lmv5
202
Types of Cable
203
Loads On Terminals
203
General Data
203
Mains Supply
203
Undervoltage
203
Oil Pump / Magnetic Clutch
203
Loads On Terminals, Cable Lengths and Cross-Sectional Areas
204
Load On Individual Contacts
204
Fan Motor Contactor
204
Alarm Output
204
Ignition Transformer
204
Fuel Valves (Gas)
204
Fuel Valves (Oil)
205
Azl5
205
Dimensions
205
Lmv5
206
Addendum 1: List of Fault Status Messages of LMV5
251
Addendum 2: Connection Diagram
252
Addendum 3: Variable Speed Drive (VSD) Module
252
General
252
Basic Diagram
252
Lmv51
252
Lmv52
253
Alarm Input X73-3
253
Connection Diagram
253
General
253
Inputs / Outputs
253
Release Contact X73-1 / -2
253
VSD Module
254
Speed Feedback Signal
254
Speed Input X70
254
Sensor Disk
254
Speed Sensor
254
Selection of Fan Motor
255
Configuration of VSD
255
Fuel Meter
255
Fuel Meter Input X71 / X72
256
Configuration of Speed Acquisition
256
Standardization
256
Note
257
Settling Time
258
Configuration of Current Interface
258
Configuration of Fuel Meter
258
Pulse Value Gas
258
Pulse Value Oil
259
Fuel Meter Readings
259
Process Data
Advertisement
Siemens LMV51 Series Basic Documentation (278 pages)
Burner Control with integrated Fuel / Air Ratio Control, Burner Control with Load Control and Oxygen Trim Control for Forced-draft Burners
Brand:
Siemens
| Category:
Control Unit
| Size: 4.61 MB
Table of Contents
4
Table of Contents
23
Block Diagram Inputs / Outputs
24
Block Diagram (Cont'D)
25
Block Diagram (Cont'D)
26
Fuel Train Applications (Examples)
26
Direct Gas Ignition
26
Gas Pilot Ignition 1
26
Gas Pilot Ignition 2
26
Fuel Valve Control Program
27
Fuel Train Applications (Cont'D)
27
Direct Ignition with Light Oil, Multistage
28
Direct Ignition with Light Oil, Modulating
28
Fuel Valve Control Program
29
Direct Ignition with Heavy Oil, Multistage
29
Direct Ignition with
29
Heavy Oil, Modulating
29
Fuel Valve Control Program
31
Dual-Fuel Burner Gas / Light Oil with Gas Pilot Ignition
31
Fuel Valve Control Program
32
Dual-Fuel Burner Gas / Heavy Oil with Gas Pilot Ignition
32
Fuel Valve Control Program
33
Burner Control
33
Description of Inputs and Outputs
33
Flame Signal Input and Flame Detector X10-01 and X10-03
33
Self-Test Function LMV5
33
Technical Data Flame Supervision
33
QRI (Suited for Continuous Operation)
34
IONIZATION (Suited for Continuous Operation)
34
Qrb
35
Digital Inputs
35
Safety Loop X3-04
35
Flange X3-03
35
Inputs for External Controller (ON/OFF) X5-03
35
Inputs (on / off or STAGE2 / STAGE3)
35
X5-03
36
Air Pressure Switch (APS) X3-02
36
Pressure Switch-VP-Gas / LT or Closed Position Indicator (CPI) X9-03
36
Pressure Switch-Min-Gas, Start Release Gas (Psmin-Gas) X9-03
36
Start Release Gas X7-03 (Only LMV52
37
Pressure Switch-Max-Gas, (Psmax-Gas) X9-03
37
Pressure Switch-Min-Oil (Psmin-Oil) X5-01
37
Pressure Switch-Max-Oil (Psmax-Oil) X5-02
37
Start Release-Oil (START) X6-01
38
Direct Heavy Oil Start (HO-START) X6-01
38
Fan Contactor Contact (FCC) or FGR-PS X4-01
39
Digital Outputs
39
Alarm Output, Type No-SI X3-01
39
Output Fan, Type No-SI X3-01
39
Output Ignition, Type si (IGNITION) X4-02
39
Outputs Valves-Oil , Type si (V
39
Outputs Valves -Gas, Type si (V
40
Output Oil Pump / Magnetic Clutch, Type No-SI X6-02
40
(Start) X4-03
41
Program Sequence
41
Parameters
41
Time Parameters
42
Gas Valve Proving
42
Recommendation
43
Determination of VP Leakage Rate
44
Special Functions During the Program Sequence
44
Lockout Phase (Phase 00)
44
Safety Phase (Phase 01)
44
Reset / Manual Lockout
44
Characteristics
45
Signaling Start Preventions
45
Forced Intermittent Operation
45
Program Stop Function
46
Gas Shortage Program
46
Sequence Diagram
46
Part Load Shutdown
47
Normal / Direct Start
47
Continuous Fan Operation
47
Response to Extraneous Light in Standby
48
Selection of Fuel
48
Selection of Fuel with
48
The Fuel Selector on the LMV5
48
On the AZL5
48
Selection of Fuel Via BACS
48
Fuel Changeover
49
Sequence Diagrams
49
Direct Gas Ignition
50
Gas Pilot Ignition 1
51
Gas Pilot Ignition 2
52
Light Oil Direct Ignition
53
Heavy Oil Direct Ignition
54
Light Oil with Gas Pilot Ignition
55
Heavy Oil with Gas Pilot Ignition
56
Legend to the Sequence Diagrams
57
Fuel / Air Ratio Control (FARC)
57
General
57
Program Sequence
57
Standby
57
Preventilation
58
Ignition
58
Traveling to the Operating Position
58
Operation
58
End of Operating Position
59
Postpurging
59
Actuator Speed Outside Normal Operation
59
Operating Position
59
Modulating
60
Multistage Operation
61
Position Check
61
Dynamic Safety Time Ratio Control
63
Outside the Operating Position
63
Operating Position Modulating
63
Operating Position Multistage
63
Special Features
63
Program Stop
63
Direction of Rotation of Actuators
64
Limitation of the Load Range
65
Activation of Actuators / VSD
65
Lmv51
65
Lmv52
65
Number of Fuel Actuators
65
Traveling Times
65
Shutdown Behavior
66
Temperature or Pressure Controller (Internal Load Controller LC)
66
General
66
Connection Diagram
66
Operating Modes with the Load Controller
67
Operating Mode 1 (Extlc X5-03)
68
Operating Mode 2 (Intlc)
68
Operating Mode 3 (Int LC Bus)
69
Operating Mode 4 (Int LC X62)
69
Operating Mode 5 (Ext LC X62)
70
Operating Mode 6 (Ext LC Bus)
70
Operating Mode Changeover to Internal Load Controller
71
Control (Characteristics)
71
Operating Mode
71
Integrated 2-Position Controller (C = on / OFF)
71
General
71
Switching Differentials
72
Modulating Control
72
General
72
Function Diagrams
72
Control Parameters
72
Manual Setting of the Control Parameters
73
Self-Setting of Control Parameters (Adaption)
73
Adaption Sequence
74
Checking the Control Parameters
74
Example
75
Settling of the Manipulated Variable
75
Principle
75
Description (Graph)
76
Multistage Control
76
General
76
Load-Dependent Activation of the Higher Burner Stages
77
Function Diagrams
78
Actual Values (X)
78
Input 1, TEMP, Pt100 Sensor (DIN) X60
78
Input 2: TEMP. / PRESS INPUT, DC 0
78
X61
78
Measuring Range Temperature (Can be Parameterized)
78
Measuring Range Pressure (Can be Parameterized)
79
Input 4: TEMP, Pt1000 / LG-Ni 1000 X60
80
Setpoints (W)
80
Internal Setpoint
80
Input 3: SET POINT INPUT X62
80
External Predefined Setpoint
80
External Predefined Load
80
External Predefined
81
External Predefined Load, Multistage
81
External Setpoint Changeover
81
External Setpoints or Predefined Load Via Digital E-Bus Interface
82
Integrated Temperature Limiter Function
82
TL Within the Scope of TRD
82
TL with External Predefined Load
82
Requirements Placed on Sensor and Protection Pocket
83
Cold Start Thermal Shock Protection (CSTP)
83
CSTP - Modulating Operation
84
CSTP - Multistage Operation
84
CSTP with Temperature Sensor in Pressure Plants
85
Output
85
Output 4
85
Output, Modulating
85
Output, Multistage
85
Multiboiler Plants
85
Multiboiler Plants by Means of an Analog Input
86
Display and Operating Unit AZL5
87
Assignment of AZL5
88
Connecting Cable to the E-Bus Adapter
88
Connecting Cable to the PC
89
Ports of the AZL5
90
Port for the PC
91
Connection to Superposed Systems
91
General Information and BACS Functions
91
Reading Ebus-Specific
91
Data
92
Writing Parameters
92
List of Supported
92
Ebus Commands
93
Display and Settings
93
Menu Structure
94
Displays
95
Display (Cont'D)
96
Displays (Cont'D)
97
Lockout and Error Messages
98
Lockout and Error Messages (Cont'D)
99
Lockout and Error Messages (Cont'D)
100
Standard Parameterizations (Incl. Entry of Password)
101
Entry of Password (PW)
101
Start Display
102
First Submenu Level
102
Second Submenu Level
102
Third Submenu Level
102
Fourth Submenu Level
103
Addressing the Actuators (Function Assignment)
104
Direction of Rotation
104
Reset
104
Operational Status Indication by LED on the Actuator
104
Power Is Fed to Unaddressed Actuator
104
Button for Addressing Is Pressed (Display During Addressing Procedure)
104
Addressing Completed, Normal Operation of Actuator
105
Special Function Curve Settings FARC
115
Special Function Adaption LC
117
Burner Identification (Burner ID)
117
Makeup of Burner ID
117
Languages
117
Real Time Clock and Calendar
117
S / W Changeover
117
Backup
118
Adjustment of Contrast (Display)
118
Shutdown Function
119
Safety Check Function
119
Loss-Of-Flame Test
119
SLT Test
119
Menu and Parameter Lists
119
Azl5
148
Commissioning Instructions for the LMV5
148
Practice-Oriented Setting Instructions for the System Configuration, the Burner Control, and the Electronic Fuel / Air Ratio Control System
148
Basic Configuration
148
Parameterizing the Burner Identification (Burner ID)
148
Selecting the Fuel Trains
148
Checking the Inputs / Outputs While Taking into Account the Burner
149
Setting Gas Valve Proving
149
Addressing the Actuators
150
Selecting the Actuator's Direction of Rotation
150
Lmv51
150
Lmv52
151
Setting the Load Controller (Option)
Siemens LMV51 Series Manual (39 pages)
Burner Management System
Brand:
Siemens
| Category:
Control Unit
| Size: 1.28 MB
Advertisement
Share and save
Advertisement
Related Products
Siemens LMV51.000C2
Siemens LMV51.040C1
Siemens LMV51.040C2
Siemens LMV51.100C1
Siemens LMV51.100C2
Siemens LMV51.000C1
Siemens LMV51.140C1
Siemens LMV51.140C2
Siemens LMV51.300B2
Siemens LMV51.300B1
Siemens Categories
Control Unit
Controller
Measuring Instruments
Telephone
Cell Phone
More Siemens Manuals
×
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
×
Upload manual
Upload from disk
Upload from URL