Xerox WorkCentre 5687 Series Service Manual page 1971

Table of Contents

Advertisement

Table 8 NVM chain 9
Location NVM Name
NVM Description
09-064
FRU Total Count
Backup of CRU data: FRU
total count.
09-065
XRU PR Cycle
Backup of CRU data: XRU
Count
P/R cycle count.
09-066
FRU Web Usage
Backup of CRU data: FRU
Count
xeb usage count.
09-068
TC Setpoint
Sets target TC for devel-
oper process controls.
09-069
TCSensorCtrtVolt-
Sets TC sensor control volt-
age
age to adjust sensitivity.
09-070
TCSetupCom-
TC setup completed.
pleted
09-073
Last Pixel Count
Cumulative Pixel Count
over the last TC control
block (20 prints).
09-083
ReplenCart-
Maximum continuous run
MotRun
period.
09-087
Rep Cartridge
Toner (replenisher) car-
Empty
tridge empty status.
09-090
Waste Full Thresh-
Waste Full Print Count at
old
which 'Bottle Full' status is
confirmed.
09-093
Waste Shutdown
Maximum number of prints
Limit
allowed post waste full
before shutdown.
09-096
Developer Temp
Actual developer temp as
measured by sensor.
09-097
Humidity% RH
Actual machine humidity as
measured by sensor.
09-098
Altitude
Altitude adjustment in
metres.
09-100
Main Motor Delay
Enables or disables a delay
Flag
to the main motor and pho-
toreceptor motor run up
times by adding 1150 to
both of the read NVM val-
ues for IOT NVM.
09-101
Ambient Temp
Actual ambient temp as
measured by sensor.
WorkCentre 5687 Family
Value
Default
Location NVM Name
0 Read only
0
09-110
0 Read only
0
09-111
0 Read only
0
09-112
0
0
09-114
400 to 1200
800
(mVx10)
09-115
0 or 1
0
09-116
0 Read only
0
09-117
09-118
15 to 40 ms
30
09-119
0 or 1
0
1 to 1000 prints 32/38/45=0
09-120
55/65/75/
87=100
0 to 10000
32/38/45=0
09-121
prints
55/65/75/
87=1000
Degrees C.
0
%RH
0
09-122
0 = zero to
0
749m
1 = 750 to
1499m
2 = 1500 to
09-123
2249m
3 = 2250 to
2999m
09-124
4 = 3000+m
0=disabled
0
09-125
1=enabled
09-126
09-127
Degrees C
0
August 2007
6-79
Table 8 NVM chain 9
NVM Description
Replenisher
Replenisher capacity.
capacity
Repl. Delivery
Replenisher delivery rate.
Rate
Cumulative Disp
Total dispense time.
Time
Rep Lev Snr Fault Flag to indicate replenisher
sensor failure.
TC Sensor Fault
TC sensor fault.
Paper path fans
Paper path cooling mode.
mode
Scorotron On
Charge scorotron ON cycle
Ramp Up
in ramp up.
Dev bias On Ramp
Developer bias ON cycle in
Up
ramp up.
GridV Off Ramp
Charge scorotron grid volt-
Dwn
age OFF cycle out ramp
down.
Ozone max life
Stores the maximum prints
to make with the current
ozone filter.
Man Cleaning
Charge Scorotron Manual
Interval
Cleaning Interval. Fre-
quency in K sheets for
when a manual scorotron
cleaning request is dis-
played.
Auto Cleaning
Charge Scorotron Auto
Interval
Cleaning Interval. Fre-
quency in K sheets for
when a manual scorotron
cleaning request is dis-
played.
Num Images
Number of images deliv-
Delivered
ered.
InactivityLimit
The set limit of machine
inactivity in minutes
Dev Bias Off
Developer bias OFF cycle
Ramp Dwn
out ramp down.
Dev Bias Off
Developer bias OFF cycle
Ramp Dwn Alt
out ramp down alternative.
Dev Bias Off FS
Developer bias OFF fast
Ramp Dwn Alt
shutdown cycle out ramp
down.
Value
Default
1050 to 1787
32/38/45/
grams
55=1188
65/75/87=1750
15 to 60
35/45/55=460
decigrams/min
65/75/87=550
0 to
0
78000000ms
0
0
0
0
0=disabled
32/38/45/55=0
1=enabled
65/75/87=1
0 to 1000ms
100
0 to 1000ms
160
0 to 1000ms
32/38=80
45/55/65/75/
87=120
0 to
350k
4294967295
2 to 50
25k
2 to 50
20k
0 to
0
4294967295
120 to 4320
300
0 to 1000ms
160
0 to 1000ms
32/38/45/55=0
65/75/87=100
0 to 1000ms
32/38/45/55=0
65/75/87=100
General Procedures & Information