The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2138.7...15

CO/BO: Control word faults/alarms / STW fault/alarm

Access level: 2
Can be changed: -
Unit group: -
Min:
-
Description:
Display and BICO output for the control word of faults and alarms.
Bit field:
Bit
07
10
11
12
13
14
15
Dependency:
See also: p2103, p2104, p2105, p2106, p2107, p2108, p2112, p2116, p2117, p3110, p3111, p3112
r2139.0...15

CO/BO: Status word faults/alarms 1 / ZSW fault/alarm 1

Access level: 2
Can be changed: -
Unit group: -
Min:
-
Description:
Display and BICO output for status word 1 of faults and alarms.
Bit field:
Bit
00
01
03
06
07
08
11
12
13
14
15
Note
For bit 03, 07:
These bits are set if at least one fault/alarm occurs. Data is entered into the fault/alarm buffer with delay. This is the
reason that the fault/alarm buffer should only be read if, after "fault present" or "alarm present" has occurred, a change
in the buffer was also detected (r0944, r9744, r2121).
For bit 06, 08:
These status bits are used for internal diagnostic purposes only.
For bits 11, 12:
These status bits are used for the classification of internal alarm classes and are intended for diagnostic purposes only
on certain automation systems with integrated SINAMICS functionality.
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Signal name
Acknowledge fault
External alarm 1 (A07850) effective
External alarm 2 (A07851) effective
External alarm 3 (A07852) effective
External fault 1 (F07860) effective
External fault 2 (F07861) effective
External fault 3 (F07862) effective
Signal name
Being acknowledged
Acknowledgment required
Fault present
Internal message 1 present
Alarm present
Internal message 2 present
Alarm class bit 0
Alarm class bit 1
Maintenance required
Maintenance urgently required
Fault gone/can be acknowledged
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
High
High
Yes
Yes
Yes
Parameters
7.3 Parameters
Data type: Unsigned16
Dynamic index: -
Function diagram: 2546
Factory setting:
-
0 signal
FP
No
8060
No
8065
No
8065
No
8065
No
8060
No
8060
No
8060
Data type: Unsigned16
Dynamic index: -
Function diagram: 2548
Factory setting:
-
0 signal
FP
No
-
No
-
No
8060
No
-
No
8065
No
-
Low
-
Low
-
No
-
No
-
No
-
587