7.2.3.2

X500 DRIVE-CLiQ interface

Table 7- 7
DRIVE-CLiQ interface X500
Pin
1
2
3
4
5
6
7
8
A
B
Connector type: RJ45 socket; blanking plate for DRIVE-CLiQ interface included in the scope of delivery;
blanking plate (50 pieces) Order number: 6SL3066-4CA00-0AA0
7.2.3.3

X520 encoder system interface

Table 7- 8
X520 encoder system interface
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Connector type: SUB-D female, 15-pin
CAUTION
The encoder power supply can be parameterized to 5 V or 24 V. The encoder may be
destroyed if you enter the wrong parameters.
SINAMICS DCM DC Converter
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
Reserved, do not use
GND (0 V)
Signal name
Reserved
Clock
Clock*
P encoder 5 V/24 V
P encoder 5 V/24 V
P sense
M encoder (M)
Reserved
M sense
R
R*
B*
B
A*/data*
A/data
Additional system components
7.2 Sensor Module Cabinet-Mounted SMC30
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Electronics ground
Technical specifications
Do not use
SSI clock
Inverse SSI clock
Encoder power supply
Sense input encoder power supply
Ground for encoder power supply
Do not use
Ground sense input
Reference signal R
Inverse reference signal R
Inverse incremental signal B
Incremental signal B
Inverted incremental signal A/inverted SSI data
Incremental signal A/SSI data